3 Diagnostic Programs
04
(XMS)Memory Problem
05
(XMS) Out Of Range
06
Address Test Error
07
Toggle Bit Error
08
Interval Error
09
L1 Cache test Error
12
Data Bus Error
14
Speed Error
03xx
Board
01
DMA Test Error
04
Interval Timer Error
05
Periodic Faster Error
06
Periodic Slower Error
Update-ended Interrupt
07
Error
08
RTC Alarm Error
13
PCI Bus Error
14
PCI Bus Scan Error
15
PCI Device Access Error PCI access fails.
PCI Config Verification
16
Error
64
Satellite A100/A105 / TECRA A7 Maintenance Manual
The test pattern read out from the
extension memory is different
from the one that has been
written in this address.
Wrong parameters setup.
Interference between different
address channels.
Errors with the timer chip.
The acquired refreshing
frequency is out of the estimated
range.
The pattern read out from the L1
Cache is different from the one
that has been written in the same
address.
Interference between different
data channels.
Failure during the transfer speed
test.
DMA channel cannot transfer
data normally.
The difference between the
actual precision of the interval
timer and its theory value is out
of the permitted range. The timer
counts imprecisely.
The frequency is beyond the
standard.
The frequency is below the
standard.
R/W errors with the RTC
refreshing interrupt controller.
The PC speaker's sound source --
-counter/timer 8253 cannot
produce corresponding timing
signal.
No PCI.
PCI test fails.
Wrong PCI configuration.
3.11Error Codes and Description
As above.
Check and reset the parameters.
Test this memory chip on
multiple machines.
As above.
Reset the estimated range.
Test this unit on multiple
machines.
As above.
As above.
Repeat multiple times. Whether
there is always the same error,
replace the board.
As above.
As above.
As above.
As above.
As above.
Check the board.
As above.
As above.
Check PCI configuration on main
board or PCI Device
configuration.