Test Program for Field.
3.10 Real Time Clock Test
To execute the Real Time Clock Test select 07 from the Diagnostic Test Menu, press Enter
and follow the directions on the screen. The Real Time Clock Test contains three subtests
that test the computer's real time functions. Move the highlight bar to the subtest you want to
execute and press Enter.
Subtest 01
Real Time
This subtest allows you to change the date and time. To execute the Real Time
Subtest, follow these steps:
1. Select Subtest 01 and the following displays:
Current date : mm-dd-yyyy
Current time : hh:mm:ss
Enter new date : mm-dd-yyyy
Enter new time : hh:mm:ss
Press [Enter] key to exit test
2. If the current date is not correct, enter the correct date at the "Enter new
date" prompt and press Enter. The following prompt displays:
3. If the current time is not correct, enter the correct time using a 24-hour
format and press Enter.
NOTE: If NO is selected for Test Loop on the Test Parameter menu, the
Real Time Clock Test menu displays.
If YES is selected for Test Loop on the Test Parameter menu, the screen
above displays and the test is executed again. Press Ctrl + break to return
to the Real Time Clock Test menu.
Satellite P100 and Satellite Pro P100 Tests and Diagnostics Manual
Enter new time :
[ REAL TIME TEST
]
39