6.6.2
• Function
[Parameter setting]
6
6.7
DC braking
6.7.1
• Function
[Parameter setting]
Run/stop control with frequency setting signals
: Operation starting frequency
: Operation starting frequency hysteresis
The Run/stop of operation can be controlled simply with frequency setting signals.
Title
Function
Operation starting frequency
Operation starting frequency hysteresis
Output frequency [Hz]
+
-
DC braking
: DC braking starting frequency
: DC braking current
: DC braking time
A large braking torque can be obtained by applying a direct current to the motor. These parameters
set the direct current to be applied to the motor, the application time and the starting frequency.
Title
Function
DC braking starting frequency
DC braking current
DC braking time
0.0-
0.0-
The inverter begins accelerating after
the frequency setting signal has reached
point B.
Deceleration begins when the frequency
setting signal decreases below point A.
0
A
B
100%
0.0-
0.0-100 (%)
0.0- 20.0 (sec)
F-24
Adjustment range
Default setting
(Hz)
(Hz)
Frequency command value
Adjustment range
Default setting
(Hz)
E6581158
0.0
0.0
0.0
50
1.0