System Test - Toshiba Satellite P500 Maintenance Manual

Hide thumbs Also See for Satellite P500:
Table of Contents

Advertisement

Test Program for Field.
3.4

System Test

To execute the System Test select 01 from the Diagnostic Test Menu, press Enter and follow
the directions on the screen. The System Test contains three subtests. Move the highlight bar
to the subtest you want to execute and press Enter.
Subtest 01
FAN ON/OFF Checking
Select 1,2,3 to control FAN on/off , 1=Fan on , 2=Fan off , 3=Exit .
[BOIFAN2.EXE] Program Version : 1.0
1: Fan On 2: Fan Off 3: Exit
Fan1 Status On Fan1RPM : 5000 or Fan1 Status OFF Fan1RPM : 0
Fan2 Status On Fan2RPM : 2500 or Fan2 Status OFF Fan2RPM : 0
Subtest 02
Battery Test
This will display battery information for check , press [ESC] to exit .
[BOIPCU.EXE] Program Version : 1.0 03-27-2007
voltage
temperature
current
average current
relative state of charge : 93 %
absolute state of charge : 89 %
remaining capacity
full charge capacity
run time to empty
average time to empty
average time to full
cycle count
design capacity
design voltage
specification information : 2.1
serial no.
STATUS
Press [ESC] KEY to exit
Satellite P500 and Satellite Pro P500 Tests and Diagnostics Manual
: 12522 mV
Remaining capacity alarm
: 24.4 'C
Remaining time alarm
: 1330 mA
Battery mode
: 1327 mA
AtRate
At rate time to full
At rate time to empty
: 3546 mAh
At rate O. K.
: 3800 mAh
Maximun error
: -1 min.
Charging current
: -1 min.
Charging voltage
: 101 min.
Manufacturer name
: 10 times
Device name
: 4000 mAh
Device chemistry
: 11100 mV
Manufacturer data
Manufacture date
: 32009
: INIT
: 400 mAh
: 10 min
: 0
: 0 mA
: 65535 min
: 65535 min
: FFFF
: 2 %
: 2800 mA
: 12600 mA
: SANYO
: NS2P3SZDNVWR
: LION
: 0
: 9/13/2005
11