hit counter script
Toshiba RAS-07UKHP-E Owner's Manual

Toshiba RAS-07UKHP-E Owner's Manual

Air conditioner (split type) indoor unit and outdoor unit
Table of Contents

Advertisement

AIR CONDITIONER

CLMATISEUR (MODELE SEPARE)
KLIMAGERÄT
(GETEILTE AUSFÜHRUNG)
CONDIZIONATORE D'ARIA
(TIPO SCOMPONIBILE)
ACONDICIONADOR DE AIRE
(TIPO SPLIT)
SISTEMA DE AR CONDICIONADO
(TIPO SPLIT)
КOHДИЦИOHEP BOЗДУХA
(CПЛИT-CИCTEMA)
KLIMATSKI UREĐAJ (RASTAVLJIV MODEL)
KLIMATIZAČNÍ ZAŘÍZENÍ (DĚLENÝ TYP)
LÉGKONDICIONÁLÓ (OSZTOTT TÍPUS)
KLİMA (SPLİT TİPİ)
OWNER'S MANUAL
MODE D'EMPLOI
BEDIENUNGSANLEITUNG
MANUAL D'ISTRUZIONE
MANUAL DEL USUARIO
MANUAL DO UTILIZADOR
PУКOBOДCTBO ПO ЭКCПЛУATAЦИИ
VLASNIČKI PRIRUČNIK
UŽIVATELSKÁ PŘÍRUČKA
FELHASZNÁLÓI KÉZIKÖNYV
KULLANIM KILAVUZU
For general public use
Pour utilisation grand public
Für allgemeine Verwendung
Per l'uso in generale
Para el uso público general
Para utilização do público em geral
Oбщeго нaзнaчeния
Za opću javnu primjenu
Pro širokou uživatelskou veřejnost
Általános célú felhasználásra
Evlerde kullanım için
RAS-07UKHP-E / RAS-07UAH-E
RAS-10UKHP-E / RAS-10UAH-E
RAS-13UKHP-E / RAS-13UAH-E
Indoor Unit
Unité intérieure
Raumgerät
Unità interna
Unidad interior
Unidade Interior
Bнyтpeнний блок
Unutarnja jedinica
Vnitřní jednotka
Beltéri egység
İç Ünite
(SPLIT TYPE)
Outdoor Unit
Unité extérieure
Außengerät
Unità esterna
Unidad exterior
Unidade Exterior
Hapyжный блок
Vanjska jedinica
Venkovní jednotka
Kültéri egység
Dış Ünite
1075000801

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-07UKHP-E

  • Page 1: Air Conditioner

    (TIPO SPLIT) Evlerde kullanım için КOHДИЦИOHEP BOЗДУХA (CПЛИT-CИCTEMA) KLIMATSKI UREĐAJ (RASTAVLJIV MODEL) KLIMATIZAČNÍ ZAŘÍZENÍ (DĚLENÝ TYP) LÉGKONDICIONÁLÓ (OSZTOTT TÍPUS) KLİMA (SPLİT TİPİ) RAS-07UKHP-E / RAS-07UAH-E RAS-10UKHP-E / RAS-10UAH-E RAS-13UKHP-E / RAS-13UAH-E Indoor Unit Outdoor Unit Unité intérieure Unité extérieure Raumgerät Außengerät...
  • Page 2 Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. Avant tout, merci d’avoir porté votre choix sur un climatiseur TOSHIBA. Avant de le mettre en service, prière de lire attentivement ce mode d’emploi.
  • Page 3: Table Of Contents

    CONTENTS / SOMMAIRE / INHALT / INDICE ACCESSORIES/AIR FILTER COMPONENTS ......2 Hi POWER OPERATION ............10 PRECAUTIONS FOR SAFETY ............ 2 TIMER OPERATION ..............10 PARTS NAME ................3 MEMORY/PRESET OPERATION ..........12 NAMES AND FUNCTIONS OF INDICATORS AND ADJUSTING AIR FLOW DIRECTION ........
  • Page 4 CONTENIDOS / ÍNDICE / СОДЕРЖАНИЕ / SADRŽAJ ACCESORIOS/COMPONENTES DEL FILTRO DE AIRE ... 2 FUNCIONAMIENTO DE ALTA POTENCIA (Hi POWER) ..10 PRECAUCIONES SOBRE SEGURIDAD ........2 FUNCIONAMIENTO DEL TEMPORIZADOR ......10 NOMBRE DE LOS COMPONENTES ........... 3 MEMORIA/FUNCIONAMIENTO PREDEFINIDO ....... 12 NOMBRES Y FUNCIONES DE LOS INDICADORES Y AJUSTE DE LA DIRECCIÓN DEL FLUJO DE AIRE ....
  • Page 5 OBSAH / TARTALOMJEGYZÉK / İÇİNDEKİLER PŘÍSLUŠENSTVÍ/SOUČÁSTI VZDUCHOVÉHO FILTRU ... 2 PROVOZNÍ REŽIM VYSOUŠENÍ ..........9 BEZPEČNOSTNÍ OPATŘENÍ ............2 PROVOZ S VYSOKÝM VÝKONEM ........... 10 NÁZVY DÍLŮ ................3 POUŽITÍ ČASOVÝCH SPÍNAČŮ ..........10 NÁZVY A FUNKCE KONTROLEK A OVLÁDACÍCH PRVKŮ POUŽITÍ...
  • Page 6: Accessories/Air Filter Components

    ACCESSORIES AIR FILTER COMPONENTS Remote control Remote Batteries Purifying filter Zeo lite filter control holder (two) PRECAUTIONS FOR SAFETY DANGER • DO NOT ATTEMPT TO INSTALL THIS UNIT BY YOURSELF. THIS UNIT REQUIRES QUALIFIED INSTALLER. • DO NOT ATTEMPT TO REPAIR THE UNIT BY YOURSELF. THIS UNIT HAS NO COMPONENTS WHICH YOU CAN REPAIR.
  • Page 7: Precautions For Safety

    CAUTION CAUTIONS ABOUT INSTALLATION • Certainly lay the drain hose for perfect draining. Wrong drainage may cause flooding in the house and getting furniture wet. • Make sure to connect the air conditioner to an exclusive power supply of the rated voltage;...
  • Page 8: Parts Name

    PARTS NAME Outdoor unit 1 Drain hose, refrigerant connecting pipe and electric wires 2 Air inlet (Side and rear) 3 Air outlet (07 class) (10-13 class) Indoor unit 4 Room temperature sensor 5 Front panel 6 Air inlet grille 7 Air filter 8 Air outlet 9 Horizontal air flow louver ! Vertical air flow louver...
  • Page 9: Remote Control And Its Functions

    REMOTE CONTROL AND ITS FUNCTIONS 1 Infrared signal emitter $ Memory button (MEMO) Transmits a signal to the indoor unit. Press this button to stand by memorizing the 2 START/STOP button settings. Press the button again for more than 4 seconds to Press the button to start operation.
  • Page 10: Names And Functions Of Indications On Remote Control

    NAMES AND FUNCTIONS OF INDICATIONS ON REMOTE CONTROL Display All indications, except for clock time indication, are indicated by pressing the START/STOP button. 1 Transmission mark This transmission mark (,) indicates when the remote control transmits signals to the indoor unit. 2 Mode display Indicates the current operation mode.
  • Page 11: Clock Button

    Setting the clock Before you start operating the air conditioner, set the clock of the remote control using the procedures given in this section. The clock panel on the remote control will indicate the time regardless of whether the air conditioner is in use or not. Initial setting When batteries are inserted in the remote control, the clock panel will indicate AM 0:00 and will flash.
  • Page 12: Handling The Remote Control

    HANDLING THE REMOTE CONTROL CAUTION • The air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the indoor unit. • Prevent any liquid from falling into the remote control. Do not expose the remote control to direct sunlight or heat. •...
  • Page 13: Automatic Operation (Auto Changeover)

    AUTOMATIC OPERATION When you set the air conditioner in AUTO mode, it will automatically select cooling, heating, or fan only operation depending on the room temperature. ( see page 15.) In addition, fan speed and louver are automatically controlled. Start 1 START/STOP button AUTO Press this button to start the air conditioner.
  • Page 14: Cooling/Heating/Fan Only Operation

    COOLING/HEATING/FAN ONLY OPERATION Start 1 START/STOP button Press this button to start the air conditioner. 2 Mode select button (MODE) Select Cool , Heat , or Fan only 3 Temperature button ( Set the desired temperature. Cooling 21°C or higher. PRESET Heating 28°C or lower.
  • Page 15: Hi Power Operation

    Hi POWER OPERATION High power (Hi POWER) • The Hi POWER (high power operation) mode automatically controls room temperature, air flow and operation mode so that the room is quickly cooled in summer and warmed in winter. ( see page 15.) Setting Hi POWER mode 1 Hi POWER button Press the Hi POWER button.
  • Page 16 Combined timer (Setting both ON and OFF timers simultaneously) OFF timer —> ON timer (Operation —> Stop —> Operation) This feature is useful when you want to stop the air conditioner after you go to sleep, and start it again in the morning when you wake up or you return home.
  • Page 17: Memory/Preset Operation

    MEMORY/PRESET OPERATION Memorize the frequently used operation setting by the MEMO button for convenience. Start the air conditioner in the operation mode which you want the remote control to memorize. Press the button as follows while the air conditioner is in operation. 1 MEMO button Press this button briefly to standby memorizing the setting.
  • Page 18: Adjusting Air Flow Direction

    ADJUSTING AIR FLOW DIRECTION • Adjust the air flow direction properly. Otherwise, it might cause discomfort and make the room temperature uneven. • Adjust the vertical air flow using the remote control. • Adjust the horizontal air flow manually. Adjust the vertical air flow The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating conditions when AUTO or A mode is selected.
  • Page 19: Auto Restart Operation

    AUTO RESTART OPERATION This air conditioner is equipped with an Automatic restarting facility which allows the air conditioner to resume the set operating conditions in the event of a supply power shutdown without the use of the remote control. The operation will resume without warning three minutes after the power is restored. INFORMATION The AUTO RESTART OPERATION is not set to work on shipment from the factory, and so it is necessary to set it to function as required.
  • Page 20: How The Air Conditioner Works

    HOW THE AIR CONDITIONER WORKS Automatic Operation • The air conditioner selects and operates in one of the operating modes of cooling, heating, or fan only, depending on the room temperature. • If the AUTO mode is uncomfortable, you can select the desired conditions manually. Room temperature in operation Operating condition The set temperature +1°C or higher...
  • Page 21: Hints For Economical Operation

    DRY operation ( ) The dry mode will automatically select the cooling dry operation based on the difference between the set temperature and the actual room tempera- Cooling Fan only Cooling Fan only Cooling ture. • Cooling dry operation This operation is performed when the room temperature is higher than Time the set temperature.
  • Page 22: Maintenance

    MAINTENANCE WARNING Before you clean the air conditioner, be sure to turn off the circuit breaker, or main power switch. Cleaning of indoor unit and remote control Wipe with dry cloth CAUTION • Use a dry cloth to wipe the indoor unit and remote control. •...
  • Page 23 Insert the upper portion of air filter confirming to fit its right and left edges on the indoor unit until it is firmly set. Close the air inlet grille. * If the FILTER lamp on the indoor unit is indicated, press the FILTER button on the remote control or the TEMPORARY Filter holder button on the indoor unit to turn off the...
  • Page 24: Air Conditioner Operations And Performance

    AIR CONDITIONER OPERATIONS AND PERFORMANCE Three-minute protection feature A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on. This will protect the machine. Heating characteristics Preheating operation The air conditioner will not deliver warm air immediately after it is started.
  • Page 25: Troubles And Causes

    TROUBLES AND CAUSES CAUTION If any of the following conditions occur, stop the air conditioner immediately, set to off the main power switch and contact the dealer: • The indicator lamps blink at short intervals (5 Hz). Reset the circuit breaker 2 to 3 minutes after the power main switch is turned off.
  • Page 26 Before you ask for servicing or repairs, check the following points. The back of indoor unit is dewed. • Dewdrops on the back of the indoor unit are automatically collected and drained out. Indoor unit or outdoor unit makes a strange noise. •...
  • Page 27: Specifications

    SPECIFICATIONS Reverse cycle, Split type Type Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Model RAS-07UKHP-E RAS-07UAH-E RAS-10UKHP-E RAS-10UAH-E Power supply 50Hz, 220-240 V~ 50Hz, 220-240 V~ Cooling capacity (kW) CAPA. 2.10 ~ 2.15 2.70 ~ 2.75 Heating capacity (kW) CAPA.
  • Page 28: Troubles And Causes (Concerning Remote Control)

    TROUBLES AND CAUSES (Concerning Remote Control) Before you ask for servicing or repairs, check the following points. Setting Change Is Impossible Symptoms Causes Reason and Disposal • Check whether the MODE The fan speed cannot When the automatic mode is be changed.

Table of Contents