FILE NO. SVM-02003

SERVICE MANUAL

AIR-CONDITIONER
SPLIT WALL TYPE
RAS-13UKPX-T2 / RAS-13UAX-T2
RAS-10UKPX-T2 / RAS-10UAX-T2
RAS-07UKPX-T2 / RAS-07UAX-T2
RAS-13UKX / RAS-13UAX
RAS-10UKX / RAS-10UASX
07 Class
10/13 Class
Apr., 2002

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-13UKPX-T2

  • Page 1: Service Manual

    FILE NO. SVM-02003 SERVICE MANUAL AIR-CONDITIONER SPLIT WALL TYPE RAS-13UKPX-T2 / RAS-13UAX-T2 RAS-10UKPX-T2 / RAS-10UAX-T2 RAS-07UKPX-T2 / RAS-07UAX-T2 RAS-13UKX / RAS-13UAX RAS-10UKX / RAS-10UASX 07 Class 10/13 Class Apr., 2002...
  • Page 2: Table Of Contents

    FILE NO. SVM-02003 CONTENTS 1. SPECIFICATIONS 2. CONSTRUCTION VIEWS 2-1 Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) 2-2 Indoor Unit (RAS-13UKX, RAS-10UKX) 2-3. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX) 2-4. Outdoor Unit (RAS-10UAX-T2) 2-5. Outdoor Unit (RAS-10UASX, RAS-07UAX-T2) 3. WIRING DIAGRAM 4. SPECIFICATION OF ELECTRICAL PARTS...
  • Page 3 10-3 Outdoor Unit (RAS-10UAX-T2) 10-4 Outdoor Unit (RAS-07UAX-T2, RAS-10UASX) 11. EXPLODED VIEWS AND PARTS LIST 11-1 Indoor Unit (E-Parts Assy) 11-2 Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) 11-3 Indoor Unit (RAS-13UKX, RAS-10UKX) 11-4 Outdoor Unit (RAS-13UAX-T2) 11-5 Outdoor Unit (RAS-10UAX-T2) 11-6 Outdoor Unit (RAS-13UAX) 11-7 Outdoor Unit (RAS-10UASX, RAS-07UAX-T2) –...
  • Page 4: Specifications

    FILE NO. SVM-02003 1. SPECIFICATIONS RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2 RAS-13UKX / RAS-13UAX RAS-10UKX / RAS-10UASX MODEL RAS-13UAX-T2 RAS-10UAX-T2 RAS-07UAX-T2 ITEM Cooling 220V 220V 220V 220V 240V 220V 240V Capacity 3.65 2.70 2.10 3.70 3.75 2.60 2.60 Phase 1∅ Power source 220 – 240 Power consumption 1.05...
  • Page 5 FILE NO. SVM-02003 Note : 1 • Capacity is based on the following temperature conditions. JIS C9612-1994 Condition Temperature Cooling (DB) 27°C Indoor unit inlet air temperature (WB) 19°C (DB) 35 °C Outdoor unit inlet air temperature (WB) 24 °C Note : 2 •...
  • Page 6: Construction Views

    FILE NO. SVM-02003 2. CONSTRUCTION VIEWS 2-1. Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) Front panel Air filter Air inlet Heat exchanger Back body Air outlet Knock out system Knock out system Hanger Connecting pipe (0.43m) Drain hose (0.54m) (Flare ∅6.35) Hanger Connecting pipe (0.33m)
  • Page 7: Indoor Unit (Ras-13Ukx, Ras-10Ukx)

    FILE NO. SVM-02003 2-2. Indoor Unit (RAS-13UKX, RAS-10UKX) Front panel Heat exchanger Air inlet Air Filter Back body Air outlet Knock out system Knock out system Hanger Connecting pipe (0.43m) Drain hose (0.54m) (Flare ∅6.35) Hanger Connecting pipe (0.33m) (For 07,10 series ; Flare ∅9.52 For 13 series ;...
  • Page 8: Outdoor Unit (Ras-13Uax-T2, Ras-13Uax)

    FILE NO. SVM-02003 2-3. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX) Gas side (Flare ∅12.7) Detail Drawing Liquid side (Flare ∅6.35) ∅6 hole ∅11x14 hole 8-∅6 hole (for fixing outdoor unit) ∅25Drain outlet 4-∅11x14 hole (for ∅8-∅10 anchor bolt) Handle Fan guard Electric parts cover ∅420 Service port...
  • Page 9: Outdoor Unit (Ras-10Uax-T2)

    FILE NO. SVM-02003 2-4. Outdoor Unit (RAS-10UAX-T2) Detail Drawing ∅25 Drain hole Gas side (flare ∅9.52) Liquid side (flare ∅6.35) ∅6 Hole ∅11x14 Hole 8-∅6 Holes (For fixing the outdoor unit) Handle 4-∅11x14 Long holes (For anchor bolt ∅8-∅10) Fan guard ∅420 Electric parts cover...
  • Page 10: Outdoor Unit (Ras-10Uasx, Ras-07Uax-T2)

    FILE NO. SVM-02003 2-5. Outdoor Unit (RAS-10UASX, RAS-07UAX-T2) A Detail Drawing (Back Leg) B Detail Drawing (Front Leg) R 15 ∅6 Hole ∅6 Hole R 15 ∅11x14 Hole R 5.5 ∅25Drain outlet 2-∅11x14 hole (for ∅8-∅10 anchor bolt) Fan guard Cover PV ∅420 (11)
  • Page 11: Wiring Diagram

    FILE NO. SVM-02003 3. WIRING DIAGRAM Louver motor INFRARED RAYS RECEIVE AND INDICATION PARTS 4 5 6 7 8 9 10 11 CN25 4 5 6 7 8 9 10 11 4 5 6 7 8 9 10 11 CN04 CN07 CN13 SG01...
  • Page 12: Specification Of Electrical Parts

    FILE NO. SVM-02003 4. SPECIFICATION OF ELECTRICAL PARTS 4-1. Indoor Unit Parts name Type Specifications Fan motor (for indoor) MMF-240-20-4A-1 AC Motor with 135°C thermo fuse Thermo sensor (TA-sensor) ——— 10kΩ at 25°C Switching transformer (T01) SWT-47 Microcontroller unit (IC30) TMP87CM40AN-2C67 Heat exchanger sensor ———...
  • Page 13: Outdoor Unit (Ras-13Uax)

    FILE NO. SVM-02003 4-3. Outdoor Unit (RAS-13UAX) Parts name Type Specifications Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz Compressor PH160T2-4L2 Winding resistance (Ω) (at 20°C) 2.43 3.78 Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50/60Hz Fan motor (for outdoor) HF-240-30B Winding resistance (Ω)
  • Page 14: Outdoor Unit (Ras-07Uax-T2)

    FILE NO. SVM-02003 4-5. Outdoor Unit (RAS-07UAX-T2) Parts name Type Specifications Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz Compressor PH80T1-4C Winding resistance (Ω) (at 20°C) 4.80 8.37 Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz Fan motor (for outdoor) HF-240-20B Winding resistance (Ω)
  • Page 15: Refrigeration Cycle Diagram

    FILE NO. SVM-02003 5. REFRIGERATION CYCLE DIAGRAM 5-1. RAS-13UKPX-T2 / RAS-13UAX-T2 Indoor unit Heat exchanger Cooling 0.49m 0.39m (Connecting pipe) (Connecting pipe) ∅6.35 ∅12.7 Cross flow fan O.D.:12.7mm O.D.:6.35mm Packed valve Packed valve (∅12.7) (∅6.35) Cooling Cooling Compressor RM5515FNE96 Capillary tube ∅1.7x500S...
  • Page 16: Ras-10Ukpx-T2 / Ras-10Uax-T2

    FILE NO. SVM-02003 5-2. RAS-10UKPX-T2 / RAS-10UAX-T2 Indoor unit Evaporator Cooling 0.39m 0.49m (Connecting pipe) (Connecting pipe) ∅9.52 ∅6.35 Cross flow fan O.D.:9.52mm O.D.:6.35mm Packed valve Packed valve (∅9.52) (∅6.35) Cooling Cooling Compressor RM5510GNE94 Capillary tube ∅1.5x1200S Condenser Refrigerant R-22 : 0.85 kg. Propeller fan Outdoor unit Cooling...
  • Page 17: Ras-07Ukpx-T2 / Ras-07Uax-T2

    FILE NO. SVM-02003 5-3. RAS-07UKPX-T2 / RAS-07UAX-T2 Indoor unit Heat exchanger Cooling 0.49m 0.39m (Connecting pipe) (Connecting pipe) ∅6.35 ˘9.52 Cross flow fan O.D.: 9.52mm O.D.:6.35mm Packed valve Packed valve (˘9.52) (∅6.35) Cooling Cooling Compressor PH80T1-4C Capillary tube ∅1.5x1200S Condenser Refrigerant R-22 : 0.57 kg.
  • Page 18: Ras-13Ukx / Ras-13Uax

    FILE NO. SVM-02003 5-4. RAS-13UKX / RAS-13UAX Indoor unit Evaporator Cooling 0.39m 0.49m (Connecting pipe) (Connecting pipe) ∅6.35 ˘12.7 Cross flow fan O.D.: 12.7mm O.D.:6.35mm Packed valve Packed valve (˘12.7) (∅6.35) Cooling Cooling Compressor PH160T2-4L2 Capillary tube ∅1.7x700S Condenser Refrigerant R-22 : 0.78 kg.
  • Page 19: Ras-10Ukx / Ras-10Uasx

    FILE NO. SVM-02003 5-5. RAS-10UKX / RAS-10UASX Indoor unit Evaporator Cooling 0.39m 0.49m (Connecting pipe) (Connecting pipe) ∅9.52 ∅6.35 Cross flow fan O.D.:9.52mm O.D.:6.35mm Packed valve Packed valve (∅9.52) (∅6.35) Cooling Cooling Compressor PH102T1-4C Capillary tube ∅1.5x1400S Accumulator Condenser Refrigerant R-22 : 0.65 kg.
  • Page 20: Control Block Diagram

    FILE NO. SVM-02003 6. CONTROL BLOCK DIAGRAM 6-1. RAS-13UKPX-T2 / RAS-13UAX-T2, RAS-10UKPX-T2 / RAS-10UAX-T2, RAS-07UKPX-T2 / RAS-07UAX-T2 Main Unit Control Panel M.C.U. Operation Heat Exchange sensor Functions Display Timer • Louver Control Display Thermo. Sensor Filter Sign Display • 3-minutes Delay at Restart...
  • Page 21: Ras-13Ukx / Ras-13Uax

    FILE NO. SVM-02003 6-2. RAS-13UKX / RAS-13UAX, RAS-10UKX / RAS-10UASX Main Unit Control Panel M.C.U. Operation Heat Exchange sensor Functions Display Timer • Louver Control Display Thermo. Sensor Filter Sign Display • 3-minutes Delay at Restart Infrared Rays Signal Reciver for Compressor Fan Only Sign Display...
  • Page 22: Operation Description

    LOW+MED • Receiving of information of the operation status and judging of the information or indication of error MED+HIGH Table 7-1-1 RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2 Model Motor speed Air flow level Motor speed Air flow level Motor speed...
  • Page 23: Description Of Operation Circuit

    FILE NO. SVM-02003 7-2-2. Cooling operation 7-2. Description of Operation Circuit ([MODE] button on the remote control is set (1) When turning on the breaker, the operation lamp to the cooling operation.) blinks. This means that the power is on (or the (1) The compressor, outdoor fan and operation power supply is cut off.) display on the remote control are controlled as...
  • Page 24: Cooling Operation

    SUPER LOW position. The pattern of operation depending on the relation between room temperature and preset RAS-13UKPX-T2, RAS-13UKX temperatures is shown in Fig. 7-2-5. RAS-10UKPX-T2, RAS-10UKX RAS-07UKPX-T2 Room temp.
  • Page 25: Hi Power Mode

    The air conditioner operates at normal airflow level. Less than continues for 5 minutes (3) The Hi POWER mode can not be set in Dry or Fan only operation. Fig. 7-5-1 RAS-13UKPX-T2 RAS-13UKX Heat exchanger temperature Compressor Outdoor fan Less than continues for 5 minutes Fig.
  • Page 26: Auto Restart Function

    FILE NO. SVM-02003 7-6. Auto Restart Function 7-6-1. How to set auto restart function To set the auto restart function, proceed as follows: The indoor unit is equipped with an automatic The power supply to the unit must be on; the function restarting function which allows the unit to restart will not set if the power is off.
  • Page 27: Filter Check Lamp

    FILE NO. SVM-02003 7-6-2. How to cancel auto restart function To cancel auto restart function, proceed as follows: Repeat the setting prodedure: the unit receives the signal and beeps three times. The unit will be required to be turned on with the remote control after the main power supply is turned off.
  • Page 28: Installation Procedure

    Also, make sure the equipment is properly earthed. • Appliance shall be installed in accordance with national wiring regulations. If you detect any damage, do not install the unit. Contact your TOSHIBA dealer immediately. CAUTION • Exposure of unit to water or other moisture before installation could result in electric shock.
  • Page 29 FILE NO. SVM-02003 REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems, or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.
  • Page 30: Installation Diagram Of Indoor And Outdoor Units

    FILE NO. SVM-02003 8-2. Installation Diagram of Indoor and Outdoor Units For installation of the indoor unit, use the paper pattern on the back of the installation manual. Before installing the For the rear left and left wireless remote control piping Hook •...
  • Page 31: Installation

    FILE NO. SVM-02003 8-3. Installation 8-3-1. Optional installation parts Part Parts name Q'ty Code Refrigerant piping Liquid side : ∅6.35 mm : ∅9.52 mm (RAS-07UK, Gas side each RAS-10UK) : ∅12.70 mm (RAS-13UK) Pipe insulating material (polyethylene foam, 6 mm thick) Putty, PVC tapes each <Fixing bolt arrangement of outdoor unit>...
  • Page 32 Purifying filter* x 1 Name Others Owner’s manual Installation manual The part marked with asterisk (*) are equipped for RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2. Option : For the extension drain hose, use an optionally available RB-821SW or commercially available one. – 31 –...
  • Page 33: Indoor Unit

    FILE NO. SVM-02003 8-4. Indoor Unit 8-4-2. Cutting a hole and mounting installation plate 8-4-1. Installation place <Cutting a hole> • A place which provides the spaces around the When installing the refrigerant pipes from the rear. indoor unit as shown in the above diagram. •...
  • Page 34 Anchor bolt NOTE • Ensure all wiring is used within its electrical rating. Projection 15 mm or less 5 mm dia. hole RAS-13UKPX-T2 RAS-10UKPX-T2 Model RAS-07UKPX-T2 RAS-13UKX RAS-10UKX 7 Mounting Power source 50 Hz, 220 – 240 V Single phase screw ∅4 x 25 s...
  • Page 35 FILE NO. SVM-02003 8-4-4. Wiring connection <Stripping length of the connecting cable> <How to connect the power cord> 40 mm Earth line 10 mm For the air conditioner that does not have power cord, connect a power cord to it as mentioned below.
  • Page 36 FILE NO. SVM-02003 <How to connect the connecting cable> <How to install the air inlet grille on the indoor unit> • When attaching the air inlet grille, the contrary of Wiring of the connecting cable can be carried out without removing the front panel. the removed operation is performed.
  • Page 37 FILE NO. SVM-02003 8-4-5. Piping and drain hose installation How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center <Piping and drain hose forming> head. * Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material.) 4 mm Rear right...
  • Page 38 FILE NO. SVM-02003 <Left-hand connection with piping> 8-4-6. Indoor unit fixing Bend the connecting pipe so that it is laid within 43 mm 1. Pass the pipe through the hole in the wall, and hook above the wall surface. If the connecting pipe is laid the indoor unit on the installation plate at the upper exceeding 43 mm above the wall surface, the indoor hooks.
  • Page 39: Outdoor Unit

    FILE NO. SVM-02003 8-4-7. Drainage 8-5. Outdoor Unit 1. Run the drain hose sloped downwards. 8-5-1. Installation place • A place which provides the spaces around the NOTE outdoor unit as shown in the left diagram. • Hole should be made at a slight downward slant on •...
  • Page 40 FILE NO. SVM-02003 8-5-2. Refrigerant Piping Connection (Unit : N·m) Outer dia. 1. Cut the pipe with a pipe cutter. Tightening torque of copper pipe ∅6.35 mm 16 to 18 (1.6 to 1.8 kgf·m) Roughness Warp Obliquity 90° ∅9.52 mm 30 to 42 (3.0 to 4.2 kgf·m) ∅12.70 mm 50 to 62 (5.0 to 6.2 kgf·m)
  • Page 41 FILE NO. SVM-02003 8-5-3. Evacuating <Packed valve handling precautions> • Open the valve stem all the way out; but do not try After the piping has been connected to the indoor unit, you can perform the air purge together at once. to open it beyond the stopper.
  • Page 42: How To Set Remote Control Selector Switch

    FILE NO. SVM-02003 8-5-4. Wiring connection 8-6. How to Set Remote Control Selector Switch 1. Remove the electric parts cover from the outdoor unit. 2. Connect the connecting cable to the terminal as When two indoor units ae installed in seperated rooms, identified with their respective matched numbers on there is no need to change the selector switch.
  • Page 43: Others

    FILE NO. SVM-02003 2. Set the remote control selector switch with the 8-7. Others remote control 8-7-1. Gas leak test [B] is indicated on the liquid crystal display when For RAS-10UASX, RAS-07UAX-T2 setting remote control selector switch to B. [A] is not indicated on the display even if the selector switch is set to A.
  • Page 44 FILE NO. SVM-02003 8-7-3. Auto restart setting This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure. Information The product was shipped with Auto Restart function in the off position.
  • Page 45: Troubleshooting Chart

    FILE NO. SVM-02003 9. TROUBLESHOOTING CHART 9-2-2. Incorrect cable connection between indoor 9-1. Troubleshooting Procedure and outdoor units Follow the details of 9-2. Basic Check Items. The indoor unit is connected to the outdoor unit with 5 If there is no trouble corresponding to 9-2, check cables (Heating and Cooling model) or 3 cables whether or not there are faulty parts following (Cooling Only model).
  • Page 46: Primary Judgement

    FILE NO. SVM-02003 9-3. Primary Judgement 9-3-2. Failure diagnosis The indoor unit diagnoses the operation condition and 9-3-1. Role of indoor unit controller indicates the information of the self-diagnosis with the The indoor unit controller receives the operation lamps on the display panel of the indoor unit. commands from the remote control and executes them.
  • Page 47: Self-Diagnosis By Remote Control (Check Code)

    6. mode. is A. is B. • The display of the remote control returns to as it is C. is D. was before service mode was engaged. * This illustration is only for RAS-13UKPX-T2 RAS-10UKPX-T2 and RAS-07UKPX-T2 – 46 –...
  • Page 48 FILE NO. SVM-02003 Table 9-4-1 Diagnosis function Block level Judgement and action Check Check Block Symptom Conditioner Condition code code status Indoor Thermo. sensor short/ Continued Indicated 1. Check thermo sensor. P.C. board break. operation. when detected 2. If it is OK, check P.C. abnormal board.
  • Page 49: Troubleshooting Flowcharts

    FILE NO. SVM-02003 9-5. Troubleshooting Flowcharts 9-5-1. Power can not be turned on (No operation at all) <Preliminary checks> Operation (1) Is the supply voltage normal? (2) Is the connection to the AC output OK.? Check Items Main cause Shut off the power supply from AC outlet once and Countermeasure turn it on after 5 seconds.
  • Page 50 FILE NO. SVM-02003 9-5-2. Power can not be turned on after replacing indoor P.C. board <Checking procedure> Connect the AC Power supply Return the wiring of the Does the OPERATION Is it wired as shown power relay is returned to lamp blink? in Figure below? the normal procedure.
  • Page 51 FILE NO. SVM-02003 9-5-3. Outdoor unit does not operate Shut off the power supply from AC outlet once and turn it on after 5 seconds. Does the OPERATION lamp blink? See “ Power can not be turned on”. Does the power turn on by pushing See “...
  • Page 52 FILE NO. SVM-02003 9-5-4. Only compressor does not operate Shut off the power supply from AC outlet once and turn it on after 5 seconds. Does the OPERATION lamp blink? See “ Power can not be turned on”. Does the power turn on by See “...
  • Page 53 FILE NO. SVM-02003 9-5-5. Only outdoor fan does not operate Shut off the power supply from AC outlet once and turn it on after 5 seconds. Does the OPERATION lamp blink? See “Power can not be turned on”. Does the power turn on by See “Power can not be turned on”.
  • Page 54 FILE NO. SVM-02003 9-5-6. Only the indoor fan does not operate <Check procedure> Shut off the power supply once. Turn the power supply. Does the fan stop in Replace the P.C. board. Control P.C. board is defective. no operating status? Start the operation with low fan setting in cool operation.
  • Page 55: Troubleshooting For Remote Control (Including The Indoor P.c. Board)

    FILE NO. SVM-02003 9-6. Troubleshooting for Remote Control (Including the Indoor P.C. Board) There is no been from the indoor unit. Push the START/STOP button. The operation lamp of the air conditioner main unit does not light. Does the transmission indicator blink? Short-circuit the metal terminal at the side of the...
  • Page 56 FILE NO. SVM-02003 9-6-1 How to check the P.C. board (2) Inspection procedres (1) Operating precautions 1) when a P.C. board is judged to be defective, check for disconnection, burning, or 1) When removing the front panel or the P.C. discoloration of the copper foil pattern or this board, be sure to shut off the power supply.
  • Page 57 FILE NO. SVM-02003 (3) Checking procedure Table 9-6-1 Procedure Check Point (Symptom) Causes 1. • Application of shock voltage. Shut off the power supply and 1. Is the fuse blown? • Overload by short-circuit of the remove the P.C. board assembly from the electronic parts base.
  • Page 58 FILE NO. SVM-02003 Table 9-6-2 Approximate resistance value of thermo sensor (kΩ) Temperature 0°C 10°C 20°C 25°C 30°C Resistance value 35.8 20.7 12.6 10.0 7.92 9-6-2. How to shorten time of restart delay timer 1 Press [CLR] button while pressing [CHECK] button with a tip of a pencil.
  • Page 59 FILE NO. SVM-02003 9-6-3. P.C. Board Layout Top View Bottom View – 58 –...
  • Page 60: Part Replacement

    FILE NO. SVM-02003 10. PART REPLACEMENT 10-1. Indoor Unit Part name Procedures Remarks Front panel How to remove the front panel 1) Stop operation of the air conditioner, and turn off its main power supply. 2) Pull the air inlet grille toward you to open it and remove the air inlet grille.
  • Page 61 FILE NO. SVM-02003 Part name Procedures Remarks Heat exchanger 1) Remove the front panel, electrical part and the horizontal louver following procedure 3. 2) Remove the pipe holder at the rear side of main unit. 3) Remove the 2 screws on the heat exchanger at the base bearing.
  • Page 62: Outdoor Unit (Ras-13Uax-T2, Ras-13Uax)

    FILE NO. SVM-02003 10-2. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX) Part name Procedures Remarks Common 1) Stop the operation of air-conditioner, and procedure disconnect the power cord from the AC supply. 2) Remove Electric parts cover. Remove 7-Screws ∅4 x 10L (2-Screws ∅4 x 10L) 3) Remove the cord clamp (2-Screws ∅4 x 22L) and disconnect the connecting cable.
  • Page 63: Outdoor Unit (Ras-10Uax-T2)

    FILE NO. SVM-02003 10-3. Outdoor Unit (RAS-10UAX-T2) Part name Procedures Remarks Common 1) Stop the operation of air-conditioner, and procedure disconnect the power cord from the AC supply. 2) Remove Electric parts cover. (2-Screws ∅4 x 10L) Remove 7-Screws ∅4 x 10L 3) Remove the cord clamp (2-Screws ∅4 x 22L) and disconnect the connecting cable.
  • Page 64: Outdoor Unit (Ras-07Uax-T2, Ras-10Uasx)

    FILE NO. SVM-02003 10-4. Outdoor Unit (RAS-07UAX-T2, RAS-10UASX) Part name Procedures Remarks 2-Screws ∅4 x 22L 1) Stop the operation of air-conditioner, and Common procedure disconnect the power cord from the AC supply. 2) Remove packed valve cover and electric parts cover.
  • Page 65: Exploded Views And Parts List

    FILE NO. SVM-02003 11. EXPLODED VIEWS AND PARTS LIST 11-1. Indoor Unit (E-Parts Assy) 412 RAS-10UKX / RAS-10UKPX-T2 414 RAS-13UKX / RAS-13UKPX-T2 416 RAS-07UKPX Location Part Location Part Description Description 43T60002 Terminal Block, 3P 43T62003 Cord Clamp 3P AC300V, 20A 43T69076 P.C.
  • Page 66: Indoor Unit (Ras-13Ukpx-T2, Ras-10Ukpx-T2, Ras-07Ukpx-T2)

    FILE NO. SVM-02003 11-2. Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) Electric Parts Assembly Location Part Location Part Description Description 43T00352 Front Panel Assy 43T19302 Holder Sensor 43T09308 Inlet Grille Assy 43T49302 Plate of EVA Seal 43T03304 Back Body Assy 43T49006 Holder, Plate EVA Seal...
  • Page 67: Indoor Unit (Ras-13Ukx, Ras-10Ukx)

    FILE NO. SVM-02003 11-3. Indoor Unit (RAS-13UKX, RAS-10UKX) Electric Parts Assembly Location Part Location Part Description Description 43T00352 Front Panel Assy 43T49302 Plate of EVA Seal 43T09315 Inlet Grille Assy 43T49006 Holder, Plate EVA Seal 43T03304 Back Body Assy 43T79302 Guide Drain 43T80301 Air Filter 43T22002 Bearing 43T09309 Horizontal Louver...
  • Page 68: Outdoor Unit (Ras-13Uax-T2)

    FILE NO. SVM-02003 11-4. Outdoor Unit (RAS-13UAX-T2) 13 14 20, 24 16,18 15,17 19 : ASM-PV-CAP Location Part Location Part Description Description 43005144 Cabinet, Front 43T46311 Valve, Packed 6.35 43005143 Cabinet, Back 43T46019 Valve, Packed 12.7 43042446 Base 43T47020 Bonnet, 6.35 DIA 43T19007 Guard-Fan 43T47018 Bonnet, 12.7 DIA 43T19005 Handle...
  • Page 69: Outdoor Unit (Ras-10Uax-T2)

    FILE NO. SVM-02003 11-5. Outdoor Unit (RAS-10UAX-T2) 10, 11 8, 9 13 2 7 : CAPILLARY TUBE 20 : DRYER Location Part Location Part Description Description 43T19001 Guard, Fan 43T21323 Motor, Fan 43T20001 Fan, Propeller 43T47001 Nut, Flange 43005037 Cabinet, Front 43T19005 Handle 43T43022 Condenser 43T49001 Cushion, Rubber...
  • Page 70: Outdoor Unit (Ras-13Uax)

    FILE NO. SVM-02003 11-6. Outdoor Unit (RAS-13UAX) 20, 24 16,18 15,17 19 : ASM-PV-CAP Location Part Location Part Description Description 43005144 Cabinet, Front 43T46019 Valve, Packed 12.7 43005143 Cabinet, Back 43T47020 Bonnet, 6.35 DIA 43042446 Base 43T47018 Bonnet, 12.7 DIA 43T19007 Guard-Fan 43T47029 ASM-PV-CAP 43T19005 Handle...
  • Page 71: Outdoor Unit (Ras-10Uasx, Ras-07Uax-T2)

    FILE NO. SVM-02003 11-7. Outdoor Unit (RAS-10UASX, RAS-07UAX-T2) 10, 11 08, 09 7 : CAPILLARY TUBE Location Part Location Part Description Description 43T19311 Guard, Fan 43T54303 Relay, Over Load (RAS-10UASX) 43T20306 Fan, Propeller 43T54302 Relay, Over Load (RAS-07UAX-T2) 43T00362 Cabinet, Front 43T41402 Compressor, PH120T1-4C 43T43322 Condenser (RAS-10UASX)