2 Troubleshooting Procedures
If any other error message displays, perform Check 3.
Check 3
The IRT checks the system board. When the IRT detects an error, the system
stops or an error message appears.
If one of the following error messages (1) through (17), (24) or (25) is displayed,
go to Procedure 4.
If error message (18) is displayed, go to the Keyboard Troubleshooting
Procedures.
If error message (19), (20) or (21) is displayed, go to the 2.5" HDD
Troubleshooting Procedures.
If error message (22) or (23) is displayed, go to the USB FDD Troubleshooting
Procedures.
(1)
PIT ERROR
(2)
MEMORY REFRESH ERROR
(3)
TIMER CH.2 OUT ERROR
(4)
CMOS CHECKSUM ERROR
(5)
CMOS BAD BATTERY ERROR
(6)
FIRST 64KB MEMORY ERROR
(7)
FIRST 64KB MEMORY PARITY ERROR
(8)
VRAM ERROR
(9)
SYSTEM MEMORY ERROR
(10) SYSTEM MEMORY PARITY ERROR
(11) EXTENDED MEMORY ERROR
(12) EXTENDED MEMORY PARITY ERROR
(13) DMA PAGE REGISTER ERROR
(14) DMAC #1 ERROR
(15) DMAC #2 ERROR
(16) PIC #1 ERROR
(17) PIC #2 ERROR
(18) KBC ERROR
(19) HDC ERROR
(20) HDD #0 ERROR
(21) HDD #1 ERROR
(22) NO FDD ERROR
(23) FDC ERROR
(24) TIMER INTERRUPT ERROR
(25) RTC UPDATE ERROR
Satellite P500 and Satellite Pro500 Maintenance Manual (960-Q08)