No.
Part
5
WARNING
Reactor
assembly
Wear a pair of gloves.
(6,8 ton)
Otherwise, you will risk an injury involving a replacement
part or some other object.
1. Detachment
1) Stop the air conditioner operation, and turn off the
circuit breaker.
2) Following to works 1) to 5) in 1 of No.1 Cabinet,
remove the cabinets.
3) Remove the screws for the reactor box.
(M5 × 0.4'' (10mm), 2 pcs)
4) Remove the top plate for reactor box.
(M4 × 0.3'' (8mm), 3pcs)
5) Remove the front cover for reactor box.
(M4 × 0.3''(8mm), 4pcs, Hook at the left)
6) Remove the reactor.
(M4 × 0.3'' (8mm), 2pcs, Hook at the left)
2. Attachment
Carry out installation by following reverse procedure in the
detachment 1) to 7).
Hook the hooks on each cabinet securely into the square
holes in the supports.
Work procedure
- 283 -
Remarks
3) Reactor box
4) Top plate for reactor box
5) Front cover for
reactor box
3) Screw for reactor box
3) Screw for reactor box