Item
21. COMFORT
Cooling mode
SLEEP mode
• The preset temperature will increase as
show on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to select the hours.
(1hr, 3hr, 5hr or 9hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
Heating mode
• The preset temperature will drop down as
show on ECO operation (Item No. 9)
• Press the [COMFORT SLEEP] button to
choose the operating hours. Repeat
pressing to setect thehours.
(1hr, 3hr, 5hr or 9 hr)
• If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.
Operating system setting
22. Operation
mode
select table
• Do cut J804 for cooling only system
•
Do cut J805 for heating only system
•
Do cut both of J804 and J805 for return
to factory default.
ase plate cord heater control
23. Cord
B
Heater
Control
When TO sensor is defective or the air
conditioner is cooling operation, heater output
is turned off.
Operation flow and applicable data, etc.
TO temp.
2ºC
0 ºC
The principles of comfort sleep mode are:
• Quietness for more comfortable. When
room temperature reach setting temperature
• Save energy by changing room temperature
automatically.
• The air condition can shut down by itself
automatically.
Remarks:
1. Comfort sleep mode will not operate in dry
mode and fan only mode.
1. Purpose
Choosing the operating system as
appropriate in real condition
2.
Operation
Factory default setting prefer
"Heat pump" system. Through it is
able to cooling only system heating
only system or return to factory
default.
1. Purpose
Base plate freeze prevention of the
Heater output
outdoor unit.
2.
Operation
OFF
As shown in the figure below, the
base plate freeze preventive heater is
controlled by temperature of the
ON
outside temperature sensor (TO).
(Equivalent to 100W)
- 43 -