9.7 POWER-SELECTION OPERATION
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%,
75%, or 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
● Due to the reason that POWER-SELECTION function limits the maximum
current, inadequate cooling capacity may occur.
1. Press MENU button for enter menu setting and press TEMP. button to select
POWER-SEL
2. Enter POWER-SEL setting by press MENU button again.
3. Select POWER-SEL level by press TEMP. button.
100%
75%
4. Confi rm POWER-SEL level by press MENU button.
5. Leave from menu setting display by select EXIT.
Blink only triangle
50%
10
MANUAL DEFORST OPERATION
To defrosting the heat exchanger of the outdoor unit during Heating operation
Press and hold
: for 5 seconds , then remote control display will
show
as picture 1 for 2 seconds.
11
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
or
) is shown on remote control LCD then release the button.
2. Press
or
Rise
Decrease
Remote control
LCD
Lamp illuminates full brightness.
Lamp illuminates 50% brightness.
Lamp illuminates 50% brightness and the
operation lamp is turned off.
All lamps are turned off.
● In the examples of
and
going off.
12
AUTO RESTART FUNCTION SETTING
This product is designed so that, after a power failure, it can restart automatically
in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn ON the Auto Restart Function
• Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn OFF the Auto Restart Function
• Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Notes :
● In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.

SELF CLEANING OPERATION

13
(COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.
1
for 3 seconds until brightness level (
to adjust brightness in 4 levels.
Operation display
All turned off
, the lamp illuminates for 5 seconds before
more 2 times within
,
,
Brightness
100%
50%
50%