7-2. Operation Data
<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
RAS-25N4KVRG-ND
RAS-35N4KVRG-ND
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
RAS-25N4KVRG-ND 2.1 to 2.2 34 to 35
RAS-35N4KVRG-ND 2.3 to 2.4 38 to 39
NOTES : Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
Model name
Standard
pressure
P (MPa)
1.0 to 1.1
0.9 to 1.0
Model name
Standard
pressure
P (MPa)
Heat exchanger
Indoor
pipe temp.
fan mode fan mode
T1 (°C)
T2 (°C)
14 to 15 41 to 42
High
High
12 to 13 43 to 44
Heat exchanger
Indoor
pipe temp.
fan mode fan mode
T1 (°C)
T2 (°C)
2 to 3
High
1 to 2
High
- 22 -
Outdoor Compressor
Connecting
revolution
(rps)
High
34
High
42
Outdoor Compressor
Connecting
revolution
(rps)
High
40
High
49
piping
(m)
5
piping
(m)
5