Sign In
Upload
Manuals
Brands
Toshiba Manuals
Air Conditioner
RAS-10N3AV2-E
Toshiba RAS-10N3AV2-E Manuals
Manuals and User Guides for Toshiba RAS-10N3AV2-E. We have
2
Toshiba RAS-10N3AV2-E manuals available for free PDF download: Service Manual, Technical Handbook
Toshiba RAS-10N3AV2-E Service Manual (106 pages)
Split Type Air Conditioner
Brand:
Toshiba
| Category:
Air Conditioner
| Size: 6.87 MB
Table of Contents
Service Manual
1
Table of Contents
2
Safety Precautions
3
Warning
4
Caution
5
Specifications
6
Capacity Variation Ratio According to Temperature
7
Operation Characteristic Curve
7
Piping Materials and Joints Used
8
Refrigerant Piping Installation
8
Refrigerant R410A
8
Safety During Installation/Servicing
8
Flare Processing Procedures and Precautions
9
Minimum Thicknesses of Socket Joints
9
Processing of Piping Materials
9
Thicknesses of Annealed Copper Pipes
9
Dimensions Related to Flare Processing for R22
10
Dimensions Related to Flare Processing for R410A
10
Flare and Flare Nut Dimensions for R410A
10
Flare Processing
10
Flare and Flare Nut Dimensions for R22
11
Flare Connecting Procedures and Precautions
11
Relations between Flare Nut and Flare Seal Surface
11
Tightening Torque of Flare for R410A [Reference Values]
11
General Tools (Conventional Tools Can be Used)
12
Required Tools
12
Specifications
12
Tools Exclusive for R410A
12
Recharging of Refrigerant
13
Brazing of Pipes
14
Flux
14
Materials for Brazing
14
Reason Why Flux Is Necessary
14
Brazing
15
Piping Materials for Brazing and Used Brazing Filler/Flux
15
Prevention of Oxidation During Brazing (Diagram)
15
Types of Flux
15
Construction Views
16
Indoor Unit Diagram
16
Outdoor Unit Diagram
17
Wiring Diagram
18
Specifications of Electrical Parts
19
Refrigerant Cycle Diagram - RAS-B10N3KV2-E / RAS-10N3AV2-E
20
Refrigerant Cycle Diagram - RAS-B13N3KV2-E / RAS-13N3AV2-E
21
Operation Data
22
Control Block Diagram - Indoor Unit
23
Control Block Diagram - Outdoor Unit (Inverter Assembly)
24
Operation Description
25
Outline of Air Conditioner Control
25
Role of Indoor Unit Controller
25
Role of Outdoor Unit Controller
25
Basic Operation
27
Operation Control
27
AUTO Operation
28
Cooling/Heating Operation
28
DRY Operation
28
In Cooling Operation
29
Indoor Fan Motor Control
29
In Heating Operation
30
Outdoor Fan Motor Control
31
Capacity Control
32
Current Release Control
32
Release Protective Control by Temperature of Indoor Heat Exchanger
33
Defrost Control (Only in Heating Operation)
34
Air Direction Adjustment
35
Louver Control
35
Louver Position
35
Swing
35
ECO Operation
36
Discharge Temperature Control
37
Temporary Operation
37
Pulse Modulating Valve (P .M.V.) Control
38
Self-Cleaning Function
39
Remote-A or B Selection
40
COMFORT SLEEP Mode
41
One-Touch Comfort
41
QUIET Mode
41
FIL TER Indicator
42
Hi-POWER Mode
42
How to Set the Auto Restart Function
43
When the Unit Is in Operation
43
When the Unit Is Standby (Not Operating)
43
How to Cancel the Auto Restart Function
44
Power Failure During Timer Operation
44
Function of Push Putton
45
Operation of Remote Control
45
Remote Control
45
Daily Timer
46
Display of Remote Control
48
Before Installing the Wireless Remote Controller
49
Installation Diagram of Indoor and Outdoor Units
49
Installation Procedure
49
Fixing Bolt Arrangement of Outdoor Unit
50
Installation
50
Optional Installation Parts
50
Accessory and Installation Parts
51
Installation/Servicing Tools
52
New Tools for R410A
52
Cutting a Hole and Mounting Installation Plate
53
Indoor Unit
53
Installation Place
53
Wiring Connection
54
How to Connect Remote Controller for Wire Operation
55
Changing Drain Hose
56
Die-Cutting Front Panel Slit
56
How to Install and Remove the Drain Hose
56
Piping and Drain Hose Installation
56
How to Fix the Drains Cap
57
In Case of Bottom Right or Bottom Left Piping
57
In Case of Right or Left Piping
57
Left-Hand Connection with Piping
57
Drainage
58
Indoor Unit Fixing
58
Installation Place for the Outdoor Unit
59
Outdoor Unit
59
Refrigerant Piping Connection
59
Tightening Connection
59
5 Points for Piping Work
60
Evacuating
60
Shaping Pipes
60
Using a Vacuum Pump
60
Electrical Work
61
Packed Valve Handling Precautions
61
Stripping Length of the Connecting Cable
61
Wiring Connection (Outdoor Unit)
61
Auto Restart Setting
62
Gas Leak Test
62
Others
62
Remote Control A-B Selection
62
How to Diagnose the Trouble
63
Precautions When Handling the New Inverter (3DV Inverter)
63
Discharging Method
64
Precautions When Inspecting the Control Section of the Outdoor Unit
64
Confirmation of Power Voltage
65
First Confirmation
65
Onfirmation of Power Supply
65
Operation Which Is Not a Trouble (Program Operation)
65
Judgment by Flashing LED of Indoor Unit
66
Primary Judgment
66
How to Use Remote Controller in Service Mode
67
Self-Diagnosis by Remote Controller (Check Code)
67
Caution at Servicing
68
Indoor Unit (Including Remote Controller)
70
Judgment of Trouble by Every Symptom
70
Power Is Not Turned on (Does Not Operate Entirely)
70
Power Is Not Turned on Though Indoor P.C. Board Is Replaced
71
Only the Indoor Motor Fan Does Not Operate
72
For AC Fan Motor - Inspection Procedure
73
Troubleshooting for Remote Control
74
Outdoor Unit Does Not Operate
75
Outdoor Unit Stops in a Little While after Operation Started
75
Wiring Failure (Interconnecting and Serial Signal Wire)
75
How to Check Simple the Main Parts
76
How to Diagnose Trouble in Outdoor Unit
77
Summarized Inner Diagnosis of Inverter Assembly
77
How to Check Simply the Main Parts
78
How to Check the P.C. Board (Indoor Unit)
78
P.C. Board Layout
80
Sensor Characteristic Table
80
Indoor Unit (Other Parts) Checks
81
Outdoor Unit Checks
81
Checking Method for each Part
82
How to Simply Judge Whether Outdoor Fan Motor Is Good or Bad
83
Front Panel Replacement
84
How to Replace the Main Parts
84
Indoor Unit Parts Replacement
84
Electric Parts Box Assembly Replacement
86
Evaporator (Heat Exchanger) Replacement
87
Horizontal Louver Replacement
87
Bearing Replacement
88
Fan Motor Replacement
89
Cross Flow Fan Replacement
90
Microcomputer Replacement
91
Outdoor Unit Parts Replacement
92
Front Cabinet Replacement
93
Inverter Assembly Replacement
94
Control Board Assembly Replacement
95
Side Cabinet Replacement
96
To Replace the Fan Motor
96
Compressor Replacement
97
Reactor Replacement
97
Electronic Expansion Valve Coil Replacement
98
Fan Guard Replacement
98
TD Sensor (Discharge Pipe Temperature Sensor) Replacement
99
TE Sensor (Outdoor Heat Exchanging Temperature Sensor) Replacement
99
TO Sensor (Outside Air Temperature Sensor) Replacement
99
TS Sensor (Suction Pipe Temperature Sensor) Replacement
99
Parts for Servicing Sensors Table
100
Replacement of Temperature Sensor for Servicing Only
100
Exploded Views and Parts List
101
Indoor Unit (Part-E) Exploded View
101
Indoor Unit Exploded View
102
Wireless Remote Controller 1
102
Outdoor Unit Exploded View
103
PC Board Layout
104
Advertisement
Toshiba RAS-10N3AV2-E Technical Handbook (78 pages)
Brand:
Toshiba
| Category:
Air Conditioner
| Size: 8.91 MB
Table of Contents
Table of Contents
2
Make up of Model Number
3
Mechanical Specifications-RAS R410A Outdoor Units
4
RAS R410A Multi Split System Combinations
5
RAS - Auto Restart Function
6
Mechanical Specifications - DI/SDI R410A Single Splits
7
Electrical Specifications - DI/SDI R410A Multi Splits
8
Mechanical & Electrical Data - Air-To-Air Heat Exchangers
9
Digital/Super Digital Inverter Multi Split System Combinations
11
Digital/Super Digital Inverter Twin Splits
12
Digital/Super Digital Inverter Triple Splits
14
Digital Inverter Quad Splits
16
Digital/Super Digital Multi Split System Wiring Schematic
17
VRF System Make up Chart
18
Electrical Data - VRF Outdoor Units
19
VRF Additional Refrigerant Charge Calculations
20
Acoustic Data - MMY Indoor Units
23
Common Sensor Characteristics
24
Step by Step Wiping/Re-Addressing of VRF Systems
44
TCC-Net Controller Guidelines
46
System Configuration Menu
47
TCCJ Optional Control Accessories
49
Group Control
51
Test Operation
51
Relocation of Room Temperature Sensing from Return Air to Remote Controller
53
Quick Reference Guide
56
Automatic Restart after Power Failure
60
Condition Setting (Day, Time, Mode & Temperature)
62
Delete Settings for each Day
63
Holiday Day Omit Setting
64
Network Addressing DI/SDI and VRF Systems
70
Integration with AI Network Control
76
Air Conditioning
77
Advertisement
Related Products
Toshiba RAS-10N3AV2-A
Toshiba RAS-10N3AVR-E
Toshiba RAS-10N3AV2 Series
Toshiba RAS-10N3AV-E
Toshiba RAS-10N3AVP-E
Toshiba RAS-10N3AV2-E1
Toshiba RAS-10N3ACV Series
Toshiba RAS-10N3AV-HK1
Toshiba RAS-10N3A-M
Toshiba RAS-10N3K-M
Toshiba Categories
Laptop
Air Conditioner
TV
LCD TV
All in One Printer
More Toshiba Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL