4 Replacement Procedures
3. Remove the following screws securing the right hinge.
•
M2.5×4B
•
M2.5×6C
4. Release two hooks and slide the right hinge inside to remove it through the hole.
5. Remove the following screw securing the left hinge.
•
M2.5×6C
6. Release the hook and slide the left hinge inside to remove it through the hole.
Hook
4-94 [CONFIDENTIAL] TECRA A9/TECRA S5/TECRA P5/Satellite Pro S200 Maintenance Manual (960-633)
FLAT HEAD screw
Tapping screw
Tapping screw
M2.5×4B FLAT HEAD
M2.5×6C Tapping
Figure 4-53 Removing the hinge
×1
×1
×1
M2.5×6C Tapping
Hinge (left)
4.30 Hinge
Hinge (right)