3 Tests and Diagnostics
Select the option you want to execute and press Enter. When you select 1- SYSTEM
TEST, the following message will appear:
SYSTEM TEST NAME
SUB-TEST
PASS COUNT : XXXXX
WRITE DATA : XX
ADDRESS
SUB-TEST MENU :
01 - ROM checksum
04 – Fan ON/OFF
05 - Geyserville
06 - Quick charge
07 – DMI read
99 - Exit to DIAGNOSTIC TEST MENU
NOTE: The menu displayed by your computer may be slightly different from the one
shown above.
Select the desired subtest number from the subtest menu and press Enter. The following
message will appear:
TEST LOOP
ERROR STOP : YES (or NO)
Use the right and left arrow keys to move the cursor to the desired option.
Selecting YES of TEST LOOP increases the pass counter by one, each time the test cycle
ends and restarts the test cycle.
Selecting NO returns the process to the subtest menu after the test is complete.
Use the up and down arrow keys to move the cursor to "ERROR STOP".
Use the right and left arrow keys to move the cursor to the desired option and press Enter.
3-8
[CONFIDENTIAL]
XXXXXX
: XX
ERROR COUNT
READ DATA
: XXXXXX STATUS
: YES (or NO)
TECRA A9(S5/P5/S200) Maintenance Manual (960-633)
3.2 Executing the Diagnostic Test
xxxxxxx DIAGNOSTIC TEST VX.XX
[Ctrl]+[Break]
[Ctrl]+[C]
: XXXXX
: XX
: XXX
: test end
: key stop