3.19 Hard Disk Test Detail Status
3.19 Hard Disk Test Detail Status
When an error occurs in the hard disk test, the following message is displayed:
HDC status = XXXXXXXX
Detailed information about the hard disk test error is displayed on the screen by an eight-digit
number. The first four digits represent the hard disk controller (HDC) error status number and the
last four digits are not used.
The hard disk controller error status is composed of two bytes; the first byte displays the contents
of the HDC status register in hexadecimal form and the second byte displays the HDC error
register.
The contents of the HDC status register and error register are listed in Tables 3-3 and 3-4.
Table 3-3 Hard disk controller status register contents
Bit
Name
7
BSY
(Busy)
6
DRY
(Drive ready)
5
DWF
(Drive write fault)
4
DSC
(Drive seek complete)
3
DRQ
(Data request)
2
COR
(Corrected data)
1
IDX
(Index)
0
ERR
(Error)
PORTEGE A200 Maintenance Manual (960-499)
"0" ... HDC is ready.
"1" ... HDC is busy.
"0" ... Hard disk drive is not ready to accept any command.
"1" ... Hard disk drive is ready.
"0" ... DWF error is not detected.
"1" ... Write fault condition occurred.
"0" ... The hard disk drive heads are not settled over a track.
"1" ... The hard disk drive heads are settled over a track.
"0" ... Drive is not ready for data transfer.
"1" ... Drive is ready for data transfer.
"0" ... Not used
"1" ... Correctable data error is corrected.
"0" ... Not used
"1" ... Index is sensed.
"0" ... Normal
"1" ... The previous command was terminated with an error.
3 Tests and Diagnostics
Description
3-39