hit counter script
Toshiba MMU-AP0074MH-TR Installation Manual
Toshiba MMU-AP0074MH-TR Installation Manual

Toshiba MMU-AP0074MH-TR Installation Manual

Compact 4-way cassette type air conditioners

Advertisement

Quick Links

AIR CONDITIONER (MULTI TYPE)

Installation Manual

Indoor Unit
Model name:
Compact 4-way Cassette type
MMU-AP0074MH-TR
MMU-AP0094MH-TR
MMU-AP0124MH-TR
MMU-AP0154MH-TR
MMU-AP0184MH-TR
For commercial use
Ticari kullanım için
English
Installation Manual
1
Türkçe
Kurulum kýlavuzu
26

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba MMU-AP0074MH-TR

  • Page 1: Installation Manual

    AIR CONDITIONER (MULTI TYPE) Installation Manual Indoor Unit Model name: Compact 4-way Cassette type For commercial use Ticari kullanım için MMU-AP0074MH-TR MMU-AP0094MH-TR MMU-AP0124MH-TR MMU-AP0154MH-TR MMU-AP0184MH-TR English Installation Manual Türkçe Kurulum kýlavuzu...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3: Warning Indications On The Air Conditioner Unit

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Warning indications on the air conditioner unit Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’ work clothing. Warning indication Description In addition to such normal protective gear, wear the protective gear described below when undertaking the special...
  • Page 4: Precautions For Safety

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 3 – Precautions for Safety • Carry out the specified installation work to guard against the possibility of high winds and earthquake. If the air conditioner is not installed appropriately, a unit may topple over or fall down, causing an accident. •...
  • Page 5: Accessory Parts

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Accessory Parts Explanations given to user • Upon completion of the installation work, tell the user where the circuit breaker is located. If the user does not know where the circuit breaker is, he or she will not be able to turn it off in the event that trouble has occurred in the air conditioner.
  • Page 6: Selection Of Installation Place

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 5 – Selection of Installation Place Installation space Ensure there is sufficient space to install the unit and to perform maintenance work as and when required. Keep 15 mm or more for clearance between top plate of the indoor unit and the ceiling surface.
  • Page 7: Installation

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Installation Ceiling height Unit : m WARNING Model MMU- Installable ceiling height AP007 to AP012 type Up to 2.7 The installation of the air conditioning unit must be positioned in a location that can sufficiently support its weight and AP015 to AP018 type Up to 3.5 give protection against adverse environmental conditions.
  • Page 8: External View

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 7 – External view Opening a ceiling and Treatment of ceiling Unit: mm installation of hanging bolts The ceiling differs according to structure of building. For details, consult your constructor or interior finish 595 to 660 Ceiling open dimension 1000 or more contractor.
  • Page 9: Wireless Remote Controller

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Installation of ceiling opening and Installation of remote Level gauge (levelness: 5 mm or less) hanging bolt controller (Sold separately) Hanging bolt Indoor unit Hanging bolt For installation of the wired remote controller, follow the Installation Manual attached with the remote controller.
  • Page 10: Drain Piping

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 9 – Drain Piping Drain up Attached hose VP25 vinyl chloride pipe Drain pipe band (To be local procure) connecting port When a down-gradient cannot be secured for the (Hard socket) Attached flexible hose drainpipe, drain-up piping is possible.
  • Page 11: Refrigerant Piping

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Refrigerant Piping discharge area Refrigerant piping Permissible piping length and height difference 1. Use copper pipe with 0.8 mm or more thickness. Drain pan 2. Flare nut and flare works are also different from They vary according to the outdoor unit.
  • Page 12: Electrical Connection

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 11 – Electrical Connection Tightening connection Leak check test, evacuation and other procedure CAUTION Power supply wire and WARNING For leak check test, evacuation, addition of refrigerant, communication wires Do not apply excessive torque.
  • Page 13: Wiring Between Indoor And Outdoor Units

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette ▼ Power supply Wiring between indoor and outdoor units 220 V – 240 V ~, 50 Hz Power supply 220 V ~, 60 Hz NOTE Power supply switch / circuit breaker or power supply wiring / fuse rating for indoor units should be selected by the An outdoor unit connected with control wiring between indoor and outdoor units wire becomes automatically the accumulated total current values of the indoor units.
  • Page 14: Address Setup

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 13 – Wire connection Power supply wires and earth Wiring on the ceiling panel wire According to the Installation Manual of the ceiling REQUIREMENT panel, connect the connector (2P: Red) of the ceiling 1.
  • Page 15: Applicable Controls

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Applicable Controls Specify CODE No. [ ] with temp. setup Remote controller-less setting buttons. To set the unit to high ceiling setting, there is a method that requires the changing of the jumper blocks on the Basic procedure for changing Select SET DATA [ ] with timer time...
  • Page 16: Test Run

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 15 – Test Run Filter sign setting Remote controller sensor According to the installation condition, the lighting time The temperature sensor of the indoor unit senses room of the filter sign (Notification of filter cleaning) can be temperature usually.
  • Page 17: Maintenance

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Maintenance Wireless remote controller Remove a small screw which fixes the nameplate of the receiver unit. <Daily maintenance> 3) Slide the air intake grille buttons to detach the air intake grille from the ceiling panel.
  • Page 18 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 17 – ▼ Periodic Maintenance Mount the air filter. Mount the louver. • For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air •...
  • Page 19: Troubleshooting

    Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Troubleshooting Confirmation and check Every pushing of button used to set temperature, the error log stored in memory When an error occurred in the air conditioner, an error is displayed in order.
  • Page 20 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 19 – Check method On the wired remote controller, central control remote controller and the interface P.C. board of the outdoor unit (I/F), a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C. board) to display the operation is provided.
  • Page 21 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote AI-NET central controller display control display Auxiliary code Operation Timer...
  • Page 22 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 21 – Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote AI-NET central controller display control display Auxiliary code Operation...
  • Page 23 Batch alarm of general-purpose equipment control interface Differs according to error contents of unit with occurrence of alarm Group control follower unit error TCC-LINK — — (L20 is displayed.) Decrease of No. of indoor units TCC-LINK: TOSHIBA Carrier Communication Link. 43-EN 44-EN – 22 –...
  • Page 24: Specifications

    SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 23 – Specifications Sound power level (dBA) Weight (kg) Model Main unit (Ceiling panel) Cooling Heating MMU-AP0074MH-TR 17 (3) MMU-AP0094MH-TR 17 (3) MMU-AP0124MH-TR 17 (3) MMU-AP0154MH-TR 17 (3) MMU-AP0184MH-TR 17 (3)
  • Page 25 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette Warnings on Refrigerant Leakage Important Check of Concentration Limit The room in which the air conditioner is to be installed requires a design that in the event of refrigerant 2) When there is an effective opening with the adjacent room for ventilation of leaking refrigerant gas (opening gas leaking out, its concentration will not exceed a set limit.
  • Page 26 Installation Manual Installation Manual SMMS Compact 4-way Cassette SMMS Compact 4-way Cassette – 25 – 49-EN 50-EN...

Table of Contents