hit counter script
Mitsubishi Electric MSZ-D30 Installation Manual
Mitsubishi Electric MSZ-D30 Installation Manual

Mitsubishi Electric MSZ-D30 Installation Manual

Hide thumbs Also See for MSZ-D30:

Advertisement

SPLIT-TYPE AIR CONDITIONERS

INSTALLATION MANUAL

1. BEFORE INSTALLATION

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
• Be sure to read these safety precautions and instructions.
• After reading this manual, be sure to store it with the OPERATING INSTRUCTIONS for future reference.
• Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system.
Do not install the unit by yourself (user).
whom you purchased the unit.
Follow the instructions detailed in the installation manual.
ing, or leakage of water.
Install the unit securely in a place that can bear the weight of the unit.
If the installation location cannot bear the weight of the unit, the unit could fall
causing injury.
Perform electrical work according to the installation manual and be sure to use
an exclusive circuit. Do not connect other electrical appliances to the circuit.
Ground the unit correctly.
Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel-
ephone ground. Defective grounding could cause electric shock.
Do not damage the wires.
Be sure to shut off the main power when setting up the indoor P.C. board or
wiring.
Failure to do so could cause electric shock.
If gas leaks and accumulates around the unit, it could cause an explosion.
Do not use intermediate connection of the power cord or the extension cord.
Do not connect many devices to one AC outlet.
an electric shock, the unit falling, etc.
When plugging the power supply plug into the outlet, make sure that there is
no dust, blockage, or loose parts both in the outlet and on the plug. Verify that
the power supply plug is completely in the outlet.
If there is dust, blockage, or loose parts on the power supply plug or the outlet, it could
Depending on the installation area, install a Ground Fault Interrupt (GFI) circuit
breaker.
If the Ground Fault Interrupt (GFI) circuit breaker is not installed, an electric shock
could occur.
Perform the drainage/piping work securely according to the installation
manual.
If there is defect in the drainage/piping work, water could drip from the unit, and
damage household items.
JG79A061H01
MSZ-D30/36NA
MSY-D30/36NA
WARNING
-
-
CAUTION
Required Tools for Installation
Phillips screwdriver
Level
Scale
Utility knife or scissors
3 in. (75 mm) hole saw
Torque wrench
Wrench (or spanner)
(Could lead to death or serious injury.)
Securely attach the electrical cover to the indoor unit and the service panel to
the outdoor unit.
If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are
an electric shock.
When installing or relocating the unit, make sure that no substance other than
Any foreign substances in the refrigerant circuit can cause abnormal pressure rise
or an explosion.
Do not discharge the refrigerant into the atmosphere. Check that the refrigerant gas
does not leak after installation has been completed. If refrigerant leaks during
installation, ventilate the room.
heater, space heater, stove, etc., harmful gases will be generated.
Use appropriate tools and piping materials for installation.
The pressure of R410A is 1.6 times higher than R22. Not using the appropriate
tools and materials, or improper installation could cause the pipes to burst causing
an injury.
When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes.
If the refrigerant pipes are disconnected while the compressor is running and the
stop valve is open, air could be drawn in and the pressure in the refrigeration cycle
could become abnormally high, causing the pipes to burst.
When installing the unit, securely connect the refrigerant pipes before starting
the compressor.
If the compressor is started before the refrigerant pipes are connected and the
stop valve is open, air could be drawn in and the pressure in the refrigeration cycle
could become abnormally high, causing the pipes to burst.
Install the unit according to national wiring regulations.
(Could lead to serious injury when operated incorrectly.)
This could cause injury.
Do not install the outdoor unit where small animals may live.
If small animals enter the unit and damage its electrical parts, it could cause a
5/32 in. (4 mm) hexagonal
wrench
Flare tool for R410A
Gauge manifold for R410A
Vacuum pump for R410A
Charge hose for R410A
Pipe cutter with reamer

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSZ-D30

  • Page 1: Installation Manual

    JG79A061H01 Phillips screwdriver 5/32 in. (4 mm) hexagonal Level wrench Scale Flare tool for R410A MSZ-D30/36NA Utility knife or scissors Gauge manifold for R410A 3 in. (75 mm) hole saw Vacuum pump for R410A SPLIT-TYPE AIR CONDITIONERS MSY-D30/36NA Torque wrench...
  • Page 2: Selecting The Installation Location

    (The outdoor unit is charged with refrigerant for pipe length up to 25 ft. [7.5 m]) Pipe length Additional charge is required. Exceeding 25 ft. (7.5 m) (Refer to the table below.) MSZ-D30/36NA 2.96 oz. each 5 ft. (55 g/m) Refrigerant to be added MSY-D30/36NA 1.08 oz. each 5 ft. (20 g/m)
  • Page 3: Installation Diagram

    1-4. INSTALLATION DIAGRAM Wall hole cover (D) Use the wall hole sleeve Indoor unit (C) to prevent indoor/out- Seal the wall hole door connecting wire (A) gap with putty (H). ACCESSORIES from contacting metal Check the following parts before installation. Wall hole Attach the pipe to parts in the wall and to...
  • Page 4: Indoor Unit Installation

    2. INDOOR UNIT INSTALLATION 2-1. ATTACHING THE INSTALLATION PLATE 2-13/16 in. (70 mm) or more Ceiling 5-1/8 in. (130 mm) or more for left • Find a stud in the wall to attach installation plate (1) horizontally on the wall with screws (2). and left back piping (using spacer) •...
  • Page 5: Pipe Forming And Drain Piping

    2-4. INSTALLING THE L-JOINT 1) Install L-joint (10) on the back of the unit. Position L-joint (10) according to the piping direction. (Fig. 1) In case of bottom piping (Fig. 2) • Cut L-joint (10) at the position shown in Fig. 3. •...
  • Page 6: Drain Piping

    Rear or bottom piping from the end. 2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper part of the indoor unit on the installation plate (1). 3) Check if the indoor unit is attached securely on the installation plate (1) by moving the unit to left and right.
  • Page 7: Purging Procedures, Leak Test, And Test Run

    A inch (mm) Tightening torque No good Good Pipe diameter Clutch Clutch Wing nut inch ft•lb inch (mm) type tool type tool type tool N•m Copper (mm) (kgf•cm) pipe for R410A for R22 for R22 10 to 13 13.7 to Tilted Uneven Burred ø...
  • Page 8: Test Run

    4-2. TEST RUN 1) Insert power supply plug into the power outlet and/or Caution: turn on the breaker. • After test run or remote signal reception check, turn off the unit with the 2) Press the E.O. SW once. Test run will be performed E.O.

This manual is also suitable for:

Msz-d36naMsy-d30Msy-d30naMsy-d36nalMsz-d30naMsz-d36na ... Show all

Table of Contents