Use the specified refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct refrigerant is specified in the manuals and on the spec labels provided with our products. We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by failure to follow the instructions.
PART NAMES AND FUNCTIONS MUZ-GL09NA MUZ-GL09NAH MUY-GL09NA MUZ-GL12NA MUZ-GL12NAH MUY-GL12NA MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA Air inlet (back and side) Piping Air outlet Drain hose Drain outlet MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA Air inlet (back and side) Piping Drain hose Air outlet Drain outlet OBH733G...
Page 4
MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA Unit: inch MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA REQUIRED SPACE *1 20 in. (500 mm) or more when front and sides of the unit are clear 16-7/16 Air in 1-9/16 Air in Air out 2-holes 13/32 13/16 6-7/8 19-11/16 *2 When any 2 sides of left, right and rear of the unit are clear 3-3/16 33-1/16...
Page 12
7-2. PERFORMANCE CURVE Cooling Cooling capacity (at Rated frequency) Indoor intake air Wet-bulb temperature( F) Outdoor intake air DB temperature(°F) MUZ-GL09NA MUZ-GL09NAH MUY-GL09NA SHF at rating condition = 0.82 = 399 CFM Airflow Outdoor intake air DB temperature (°F) MUZ-GL12NA MUZ-GL12NAH MUY-GL12NA MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA SHF at rating condition = 0.77 SHF at rating condition = 0.78...
Page 13
MUZ-GL18NA MUZ-GL18NAH = 646 CFM = 646 CFM Airflow Airflow Outdoor intake air WB temperature (°F) Outdoor intake air WB temperature (°F) MUZ-GL24NA MUZ-GL24NAH Airflow = 738 CFM = 738 CFM Airflow Outdoor intake air WB temperature (°F) Outdoor intake air WB temperature (°F) This value of frequency is not the same as the actual frequency in operating.
Page 14
MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA (PSIG) (PSIG) 100 105 (°F) (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA (PSIG) (PSIG) 68 70 100 105 (°F) 68 70 100 105 (°F) Outdoor ambient temperature Outdoor ambient temperature OBH733G...
Page 15
MUZ-GL15NA MUZ-GL15NAH (PSIG) (PSIG) 58Hz 58Hz (°F) (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-GL18NA MUZ-GL18NAH (PSIG) (PSIG) 81Hz 81Hz (°F) (°F) Outdoor ambient temperature Outdoor ambient temperature MUZ-GL24NA MUZ-GL24NAH (PSIG) (PSIG) 58Hz 58Hz (°F) (°F) Outdoor ambient temperature Outdoor ambient temperature OBH733G...
Page 17
MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA MUZ-GL15NA MUZ-GL15NAH Correction of Cooling capacity Correction of Cooling total input Correction of Heating capacity Correction of Heating total input (Hz) (Hz) (Hz) (Hz) The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor The operational frequency of compressor MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA MUZ-GL18NA MUZ-GL18NAH...
ACTUATOR CONTROL MUZ-GL09NA MUZ-GL09NAH MUY-GL09NA MUZ-GL12NA MUZ-GL12NAH MUY-GL12NA MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA 8-1. OUTDOOR FAN MOTOR CONTROL The fan motor turns ON/OFF, interlocking with the compressor. [ON] The fan motor turns ON 5 seconds before the compressor starts up. [OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running.
10-4. TROUBLE CRITERION OF MAIN PARTS MUZ-GL09NA MUZ-GL09NAH MUY-GL09NA MUZ-GL12NA MUZ-GL12NAH MUY-GL12NA MUZ-GL15NA MUZ-GL15NAH MUY-GL15NA MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA Part name Check method and criterion Figure Measure the resistance with a tester. Defrost thermistor (RT61) (MUZ) Refer to 10-6. “Test point diagram and voltage”, 1. “Inverter P.C. board”, Fin temperature for the chart of thermistor.
Page 22
MUZ-GL18NA MUZ-GL18NAH R.V.coil/21S4 Smoothing MUY-GL18NA (CN721) capacitor (C63) Smoothing (MUZ) Smoothing capacitor Heater connector 208/230 V AC DB61 Back side of unit (CN722) capacitor (C62) (C61) 260 - 370 V DC (MUZ-GL18NAH) Fuse (F701) Fuse (F801) 208/230 V AC T3.15AL250V T3.15AL250V Fuse (F901) T3.15AL250V...
Page 23
11-2. MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA NOTE: Turn OFF the power supply before disassembly. OPERATING PROCEDURE PHOTOS/FIGURES 1. Removing the cabinet Photo 1 (1) Remove the screws of the service panel. (2) Remove the screws of the top panel. Screws of the top panel (3) Remove the screw of the valve cover.
OPERATING PROCEDURE PHOTOS/FIGURES 2. Removing the inverter assembly, inverter P.C. board Photo 5 Screws of the terminal (1) Remove the cabinet and panels. (Refer to section 1.) Screw of the heat sink block support and the (2) Disconnect the lead wire to the reactor and the following con- support and the separator back panel nectors:...