5.2
5.2
General
NOTICE
Cleaning interval
© Copyright 2016 ABB. All rights reserved.
Maintenance
Cleaning the compressor during
operation

Cleaning the compressor during operation

The contamination of the compressor stage (compressor wheel, wall in-
sert and diffuser) depends on the degree of purity of the taken-in air.
Deposits can form in the flow channels if salt, oil mist, exhaust gas or dust
are sucked in with the air.
Consequences of contamination:
 Impaired compressor efficiency
 Higher exhaust gas temperatures
 Increased fuel consumption
 Increased rotor unbalance
Periodic cleaning of the compressor during operation prevents or delays
any major increase in contamination. But it never replaces the regular
service work where the turbocharger is completely dismantled and the
compressor is mechanically cleaned.
If the coating of dirt is very thick and hard, the compressor can only be
cleaned manually when disassembled. This cleaning must be carried
out by an ABB Turbocharging Service Station.
The interval between periodic cleaning is very dependent on the operating
conditions. In general, cleaning should be carried out every 25 ... 100 op-
erating hours.
Should the specified cleaning intervals prove incompatible with engine
operation, please contact ABB Turbo Systems.
Operation Manual / TPS44-F.. - TPS61-F..