Summary of Contents for Mitsubishi Electric MSZ-LN18VGW
Page 1
SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-LN18VGW MSZ-LN25VGW MSZ-LN35VGW MSZ-LN50VGW MSZ-LN60VGW MSZ-LN18VGV MSZ-LN25VGV MSZ-LN35VGV MSZ-LN50VGV MSZ-LN60VGV MSZ-LN18VGR MSZ-LN25VGR MSZ-LN35VGR MSZ-LN50VGR MSZ-LN60VGR MSZ-LN18VGB MSZ-LN25VGB MSZ-LN35VGB MSZ-LN50VGB MSZ-LN60VGB English OPERATING INSTRUCTIONS Deutsch BEDIENUNGSANLEITUNG Français NOTICE D’UTILISATION Nederlands BEDIENINGSINSTRUCTIES Español MANUAL DE INSTRUCCIONES Italiano LIBRETTO D’ISTRUZIONI...
Page 2
● OPERATING INSTRUCTIONS ● ENGLISH IS ORIGINAL ONTENTS I SAFETY PRECAUTIONS I DISPOSAL I NAME OF EACH PART I PREPARATION BEFORE OPERATION I I-SEE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I AIRFLOW CONTROL MODE I ABSENCE DETECTION I I-SAVE OPERATION I ECONO COOL OPERATION...
To use this unit correctly and safely, be sure to read these operating instructions before use. AFETY PRECAUTIONS The unit should not be installed, relocated, disassembled, altered, Do not pull the power cord. or repaired by the user. • This may cause a portion of the core wire to break, which may cause •...
Page 4
It can cause malfunctions. ISPOSAL To dispose of this product, consult your dealer. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and...
AME OF EACH PART Indoor unit Remote controller Air purifying Battery replacement indicator Signal transmitting Page 5 Air inlet device section Page 14 Front panel Operation dis- Distance of signal : Wi-Fi interface play section About 6 m Page 15 Air fi...
● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Setting the installation position Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Be sure to set the remote controller in accordance with the installed position of Installing the remote controller batteries the indoor unit.
Page 7
-SEE OPERATION In the i-see control mode, the room temperature is controlled based on the sensible temperature. Press during COOL, DRY, HEAT and AUTO mode to activate the i-see control mode. • Press gently using a thin instrument. • lights. (Operation display section) •...
● OPERATING INSTRUCTIONS ● ELECTING OPERATION MODES AUTO mode (Auto change over) The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is about 2°C away from the set temperature for more than 15 minutes.
Page 9
AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direction. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
Page 10
● OPERATING INSTRUCTIONS ● IRFLOW CONTROL MODE BSENCE DETECTION Airfl ow Control mode offers air conditioning according to a location of This function automatically changes the operation to No occupancy an occupant in a room detected by i-see Sensor. energy-saving mode or No occupancy Auto-OFF mode when nobody is in the room.
SAVE OPERATION CONO COOL OPERATION Swing airfl ow (change of airfl ow) makes you feel cooler than station- ary airfl ow. The set temperature and the airfl ow direction are automatically changed by the microprocessor. It is possible to perform cooling operation with A simplifi...
Page 12
● OPERATING INSTRUCTIONS ● IGHT MODE OPERATION IR PURIFYING OPERATION NIGHT MODE operation changes the brightness of the operation In the AIR PURIFYING operation, the indoor unit built-in device reduces indicator, disables the beep sound and limits the noise level of the airborne fungi, viruses, mold, and allergens.
OWERFUL OPERATION IMER OPERATION (ON/OFF TIMER) Press during COOL or HEAT mode page 7 Press during operation to set the timer. start POWERFUL operation. (ON timer) : The unit turns ON at the set time. Fan speed : Exclusive speed for POWERFUL mode Horizontal vane : Set position, or downward airflow position during (OFF timer) : The unit turns OFF at the set time.
● OPERATING INSTRUCTIONS ● EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and...
LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. • Do not use water hotter than 50°C. •...
Page 16
(ii) system or product fault; or (iii) loss or damage to any system or product; operation. which is caused by or arises from connection to and/or use of any third party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi Electric equipment. For the latest information regarding MELCloud from Mitsubishi Electric Corporation, please visit www.melcloud.com.
HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Even if these items are checked, when the unit does not recover from the Remote controller trouble, stop using the air conditioner and consult your dealer. The display on the remote •...
Page 18
● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED In the following cases, stop using the air conditioner and consult your dealer. • When water leaks or drips from the indoor unit. • When the operation indicator lamp blinks. •...
MERGENCY OPERATION UTO RESTART FUNCTION When the remote controller cannot be used... If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set Emergency operation can be activated by pressing the emergency operation with the remote controller just before the shutoff of the main power.
● OPERATING INSTRUCTIONS ● PECIFICATIONS Set name MSZ-LN25VG(HZ) MSZ-LN35VG(HZ) MSZ-LN50VG(HZ) MSZ-LN60VG Model Indoor MSZ-LN18VG MSZ-LN25VG MSZ-LN35VG MSZ-LN50VG MSZ-LN60VG Outdoor MUZ-LN25VG(HZ) MUZ-LN35VG(HZ) MUZ-LN50VG MUZ-LN50VGHZ MUZ-LN60VG Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Power supply ~ /N, 230 V, 50 Hz Capacity Input 0.485...
Page 21
Scandinavian Branch Hammarbacken 14, P.O. Box 750 SE-19127, Sollentuna, Sweden UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB, England, U.K. Polish Branch Krakowska 50, PL-32-083 Balice, Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş Şerifali Mah. Kale Sok. No:41 34775 Ümraniye, İstanbul/Turkey...
Page 22
EK MEGFELELŐSÉGI NYILATKOZAT ДЕКЛАРАЦІЯ ВІДПОВІДНОСТІ НОРМАМ ЄС MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD AMATA NAKORN INDUSTRIAL ESTATE 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...