20. Short Timer
In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
21. Hi-POWER
([Hi-POWER] button on the remote controller
Mode
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi-
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
• The indoor unit operates in according to the
2. Cooling operation
• The preset temperature drops 1ºC
3. Heating operation
• The preset temperature increases 2ºC
4. The Hi-POWER mode can not be set in Dry
and Fan only operation
Operation flow and applicable data, etc.
current operation.
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
j
k
l
m
n
4
3
∗ The Hi-POWER operation will be cancelled
when press [Hi-POWER] button again.
- 49 -
Description
Press [
] button to turn the unit OFF.
Set the operation mode or plasma air
purifier on the remote control without
sending the signal to the unit.
Use the tip of the pencil to push the
[CHK] button and hold, "00" will show
on display, them press [SET] button
to make "00" disappear.
Press [
] button to turn the unit ON.
When short timer is activated, all
setting on the remote operates
immediately, besides, all indicatiors on
front panel turns ON continuously for
3 seconds.