Lower Air Outlet Louver Control - Toshiba RAS-25U2FVG-ND Service Manual

Hide thumbs Also See for RAS-25U2FVG-ND:
Table of Contents

Advertisement

Item
Operation flow and applicable data,etc
8. Air outlet
< How to set to change upper-flow at Bi-flow setting in
selection
cooling
1. Stop operation.
2. Push and hold AIR OUTLET SELECT button on the unit
operation panel over 10seconds (less than 20seconds).
3. After holding 10seconds, 4 beep sounds in heard and
TEMPERATURE indicator displays "1" for 5seconds.
Release AIR OUTLET SELECT button.
9. Lower air
< How to open or close the lower louver at standby mode >
outlet louver
1. Push AIR OUTLET SELECT button on the unit operation
control
panel.
2. When lower louver is closed, lower louver moves to open
position and TEMPERATURE indicator displays
"OP" (OPEN) during louver moving.
When lower louver is opened, lower louver moves to open
position and TEMPERATURE indicator displays "CL"
(CLOSE) during louver moving.
<Close->Open>
< Louver position in operation >
Lower louver is controlled in operation as below.
AIR OUTLET SELECT button
AIR OUTLET SELECT button
<Open->Close>
TMPERATURE indicator
- 41 -
Description
1. Purpose
When something is dropped to inside
of the unit from upper air outlet, this
function helps to remove something
from lower air outlet