INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Air fi lter
6
Filter
5
Filter
3
Batteries
2
Wireless remote control
7
Mounting screw
CAUTION
Install in rooms that are 13 m³ or larger.
If a leak of refrigerator gas occurs
inside the room, an oxygen defi ciency
can occur.
Optional Installation Parts
Part
Parts name
code
Refrigerant piping
Liquid side : Ø6.35 mm
A
Gas side
: Ø9.52 mm
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
Putty, PVC tapes
C
50 mm or more
8
Flat head
wood screw
9
Insulation sheet
Q'ty
each
each
1
Installation plate
4
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple ! and cap
water proof " to the bottom plate of the outdoor unit before installing it.
One
28 mm
1
One
6
Do not allow the drain hose to get
slack.
50 mm or more
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Shield pipe
Right
Rear right
Bottom right
Insulate the refrigerant pipes
separately with insulation, not
together.
Saddle
Extension drain hose
8 mm thick heat resisting
(Not available, provided
by installer)
polyethylene foam
In case of right or left piping
108 mm
125 mm
Air inlet
Air outlet
90 mm
600 mm
Drain outlet
Cut the piping
hole sloped
slightly.
Left
Rear left
Bottom left
Cut dot-line area
* Drain nipple and cap
water proof are packed
in outdoor unit.