SAVE THESE INSTRUCTIONS. This sheet contains important instructions for Toshiba 1700 Series Transformer Modules.
These instructions should be followed during the installation of the transformer module.
The ambient temperature range in which this unit should be operated or stored is 32° F to 104 F (0° C to 40 C).
This module should not be opened under any circumstances. There are no user servicable parts inside. For service
contact your local Toshiba representative, or contact the Toshiba UPS marketing department toll-free at (800) 231-
1412.
When adding transformer modules, be sure to use the proper model unit.
CAUTION
Inspection/Installation
After Unpacking:
1) Check the unit for loose, broken, bent or otherwise damaged parts. If damage has occurred during shipment, keep all
original packing materials for return to shipping agent. Warranty will not apply to units damaged during shipment.
2) Check to see that the rated capacity and the model number specified on the nameplate conform to the order
specifications.
Installation Precautions
This transformer module is intended for use with a Toshiba 1700 Series UPS. Any electrical or mechanical
modifications to this equipment, without prior written consent of Toshiba International Corporation will void all
warranties and may void UL/CUL listing. Unauthorized modifications also can result in personal injury, death, or
destruction of the equipment. When installing this transformer module follow all installation instructions and precautions
as listed in the 1700 Series user manual.
Module Layout
Toshiba 1700 Series UPS
Option Module Connection Guide

IMPORTANT SAFETY INSTRUCTIONS

Misuse of this equipment could result in human injury and equipment damage. In no event will
Toshiba Corporation be responsible or liable for either indirect or consequential damage or injury that
may result from the use of this equipment.
Figure 1
Specifications
Model Number
Capacity
Single phase
Input voltage
Input
frequency
Input capacity
Input power
Approximately unity (0.95 to 1.0)
factor
Output
Single phase
voltage
Output
voltage
regulation
Output
50/60 Hz (+/- 0.5% in free running
frequency
mode, line sync range +/-1%)
Rated load
power factor
Rated output
current (rms)
UF1-IO-
024-6AA
024-6EE
2400VA
2400VA
(1.68kW)
(1.68kW)
Single phase
120VAC
230VAC
45 to 65 Hz
2400VA
2400VA
Single phase
120VAC
230VAC
Within +/- 3%, steady state
0.7
20A
10A
55611-001

Advertisement

loading

Summary of Contents for Toshiba 55611-001

  • Page 1: Important Safety Instructions

    Installation Precautions This transformer module is intended for use with a Toshiba 1700 Series UPS. Any electrical or mechanical modifications to this equipment, without prior written consent of Toshiba International Corporation will void all warranties and may void UL/CUL listing. Unauthorized modifications also can result in personal injury, death, or destruction of the equipment.
  • Page 2 UPS Connections Standard Unit with 120V Isolation Module Figure 2 shows the standard unit, consisting of one electronics module and one battery module, with the addition of the 120V isolation transformer module. Figure 2 : 120V Isolation Transformer Module Configuration The modules do not have to be stacked for the unit to operate;...

This manual is also suitable for:

1700 seriesUf1-io-024-6aaUf1-io-024-6ee