5-3. RAS-18UFP-AR4 / RAS-18UA-AR4
0.39m
(Connecting pipe)
∅12.70 mm
0.39m
(Flexible pipe)
∅12.70 mm
P
O.D.:12.70 mm
Packed valve
(∅12.70)
Accumulator
Compressor
PH340X3C-4KTS1
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Multi blade fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
exchanger interchanging
pressure P
pipe T (°C)
(MPaG)
0.4
0.5
0.3
– 23 –
FILE NO. SVM-05015
T
Packed valve
(∅6.35)
Capillary tube
∅2.0x1000S
Capillary tube
∅0.8x1200S
Refrigerant
R-22 1.20 kg
Mark (
) means check points of Gas Leak
Fan speed
(indoor)
10.0
High
13.0
High
2.0
Low
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
52/31
21/15
21/15