hit counter script

Table Of Parameters And Data; Frequency Setting Parameter; Basic Parameters - Toshiba Q9 Plus Bypass ASD Installation & Operation Manual

Hide thumbs Also See for Q9 Plus Bypass ASD:
Table of Contents

Advertisement

11. Table of parameters and data

11.1 Frequency setting parameter

Title
Function
Operation

frequency of
operation panel

11.2 Basic parameters

 Five navigation functions
Communication
Title
No.
-
History function

0090
Application easy

setting *10
0093
Guidance function

0094
Overload

characteristic
selection
0000
Automatic

acceleration/
deceleration
0001
Torque boost

setting macro
function
*10: Refer to section 11.8 about parameters that are set by this parameter.
Minimum
setting unit
Unit
Panel/Comm
unication
Hz
0.1/0.01
-
Minimum
setting unit
Function
Unit
Panel/Commun
ication
-
-
-
-
-
-
-
-
-
-
-
-
Adjustment range
Adjustment range
Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
0: -
1: Initial easy setting
2: Conveyor
3: Material handling
4: Hoisting
5: Fan
6: Pump
7: Compressor
0: -
1: -
2: Preset speed guidance
3: -
4: Motor 1 & 2 switching operation
guidance
5: Motor constant setting guidance
6: -
0: -
1: Constant torque characteristic
(150%-60s)
2: Variable torque characteristic
(120%-60s)
0: Disabled (manual setting)
1: Automatic
2: Automatic (only at acceleration)
0: -
1: Automatic torque boost + auto-
tuning
2: Vector control + auto-tuning
3: Energy saving + auto-tuning
K-1
E6581611
User
Default setting
Reference
setting
0.0
3.2.2
Default
User
Reference
setting
setting
-
6.1.1
0
6.1.2
0
6.1.3
0
5.6
6.18
0
5.2
6.1.4
0
6.1.5
11

Advertisement