4 Repair
4.7.4 Replacing the power supply
Continued
Removing the power supply
Use this procedure to remove the power supply.
Preparations before removing the power supply
1
2
Removing the power supply
1
2
3
Continues on next page
322
Action
DANGER
Turn off all:
•
electric power supply
•
air pressure supply
to the robot, before starting the repair work on the
robot.
Check if there is enough space beneath the robot
to remove the bottom cover. If not:
•
Place the robot in its calibration position.
•
Remove the fastening screws.
•
Put the robot on a flat and stable surface
in the following position:
Action
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
Remove the bottom cover.
CAUTION
Be careful not to damage the cables.
Remove the plastic covers on the connectors on
the side of the power supply.
© Copyright 2015 - 2016 ABB. All rights reserved.
Note
xx1500000370
Note
xx1500000268
xx1500000286
Product manual - IRB 14000
3HAC052983-001 Revision: D