INSTALLATION DIAGRAM OF INDOOR UNIT

INSTALLATION DIAGRAM OF INDOOR UNIT
Air fi lter
6
Filter
5
Filter
3
Batteries
2
Wireless remote control
8
Pan head
wood screw
7
9
Mounting screw

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side : ∅6.35 mm
: ∅9.52 mm
Gas side
A
(RAS-B10, 13U2FVG-E)
: ∅12.7 mm
(RAS-B18U2FVG-E)
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
C
Putty, PVC tapes
1
50 mm or more
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
4
Remote control holder
Insulation sheet
Q'ty
One
each
1
One
each
Installation plate
50 mm or more
Shield pipe
6
Do not allow the drain hose to get
slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Rear left
Bottom right
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
In case of right or left piping
Cut dot-line area
Left